06/30/17
Copyright © 2017, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
Harmony Series H2 Mortise Lock
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
5
Typical Harmony Mortise Lock Application Diagram (12/24VDC System)
12 Conductor
ElectroLynx Harness
From McKinney
Harmony Series H2
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
120 VAC
Input
12/24VDC
H N G
- +
Black (Hot)
White (Neutral)
Gr
een (Gnd)
(-)
12/24VDC
(+)
DATA 1
DATA 0
RX
RX
Electronic
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock Relay
(NO) Fail
Secure
Operation
DPS
DPS
Not Used
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO/NC) - Orange, 5
RX (COM) - Blue, 6
*EGND- Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
QC12 Electric
Hinge From
McKinney
Lock body
Power Supply
(By Others)
This product is polarity sensitive; if the lock
does not operate, check the polarity of the
input and reverse if necessary.
12/24VDC System
• Reader Draw = 150mA @12 or 24VDC
• Actuator Draw = 15mA continuous
• Total system Draw = 550mA @12/24VDC
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet A8191 for the wiring of
RX & DPS outputs.
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
ULC-S319 compliance:
EAC power supply utilizing battery backup
(30 minutes operation) is required.
UL294 Listed
EAC Panel
Reader Electronics
Require 12 or 24VDC UL294 Listed,
Power Limited Power Supply (or UL603)
Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603)