![Assa Abloy Sargent Harmony H2 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/assa-abloy/sargent-harmony-h2/sargent-harmony-h2_installation-instructions-manual_2988449015.webp)
06/30/17
Copyright © 2017, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
Harmony Series H2 Mortise Lock
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
15
9 Installing Controller
1. Feed controller harness earth ground into and around behind rim
of large upper hole of the mounting plate (Fig. 9A, B).
Fig. 9B
Earth
ground
2. Connect ElectroLynx harness (4 and 8-pin) from door harness to
ElectroLynx harness on interior PCB assembly (Fig. 9A, D).
NOTES: Neatly fold the wires into the remaining space to prevent
pinching wires when mounting escutcheon.
Do not tuck extra mortise lock body wires back
inside the lock body cylinder hole.
Connectors go on only one way.
Do not offset connector and be sure they are
completely seated.
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock Neg
Actuator (+)
Solenoid (-)
3-Pink
DPS (NC)
1- Black
PWR NEG
3-White
DATA 1
5-Orange
RX (NO/NC)
7-Brown
EGND
2-Gray Lock Pos
Actuator (+)
Solenoid (-)
4-Tan
DPS (COM)
2-Red
PWR POS
4-Green
DATA 0
6-Blue
RX (COM)
8-Yellow
LED
Connect Reader
P5
8-pin
ElectroLynx
4-pin
ElectroLynx
J5
Fig. 9A
1. Connect P5 (7 Pin Connector) from reader board to J5 on interior
escutcheon PCB assembly (Fig. 9C).
Inside of
Door
Inside of
Door
J1
J2
P5
Fig. 9C
Fig. 9D
Controller PCB
Connect ElectroLynx
®