Copyright © 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1030-020 Rev 6 11/20
13
D6021/D6031 Double Unit Series
(Push Side) Power Operator
Power Operators
1. Open door on union assembly and place each selector
mode switch in ‘OFF’ position. (Figure 27)
2.
Turn On/Off switch to ‘OFF’ position on conduit assembly.
(Figure 27)
3. Turn on building power.
4.
Turn On/Off switch to ‘ON’ position on conduit assembly.
See page 17 for controller adjustment options.
• To scroll through menu items, push up or down on
joystick. (Figure 27)
• To change setting of a menu item, when cursor is on that
item, push joystick left/right to increase/decrease value.
NOTE: Values will auto-save 3 seconds after
adjustments.
5. Set ‘HOME’ procedure for both doors.
• With door closed and union assembly selector mode
switch in “OFF” position, use joystick to scroll down
menu on LCD screen to “Home”.
• Push in on joystick to activate menu feature. Display
changes to “Set Close Limit”.
• Push in on joystick again, while door is still closed, to set
Home or closed position (Figure 28). Display changes to
“Set Open Limit”.
• Open door to desired open position (Figure 28) and
push in on joystick again. Display changes to
“Closing to Home”.
• Allow door to fully close again (Figure 28). Display
changes to “Home”.
NOTE: Values will auto-save.
Figure 27
Figure 28
View From Floor
Union Assembly
Selector Mode Switches