background image

Copyright © 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole 

or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

80-9360-1030-020  Rev 6  11/20

13

D6021/D6031 Double Unit Series

 (Push Side) Power Operator

Power Operators

1.  Open door on union assembly and place each selector 

mode switch in ‘OFF’ position. (Figure 27) 

2. 

Turn On/Off switch to ‘OFF’ position on conduit assembly. 

(Figure 27) 

3.  Turn on building power. 

4. 

Turn On/Off switch to ‘ON’ position on conduit assembly. 

See page 17 for controller adjustment options.

•  To scroll through menu items, push up or down on 

joystick. (Figure 27)

•  To change setting of a menu item, when cursor is on that 

item, push joystick left/right to increase/decrease value.

 

 

NOTE: Values will auto-save 3 seconds after 

adjustments.

 

 

5.  Set ‘HOME’ procedure for both doors.

•  With door closed and union assembly selector mode 

switch in “OFF” position, use joystick to scroll down 

menu on LCD screen to “Home”.

•  Push in on joystick to activate menu feature. Display 

changes to “Set Close Limit”.

•  Push in on joystick again, while door is still closed, to set 

Home or closed position (Figure 28). Display changes to 

“Set Open Limit”.

•  Open door to desired open position (Figure 28) and 

push in on joystick again. Display changes to  

“Closing to Home”.

•  Allow door to fully close again (Figure 28). Display 

changes to “Home”.

 

 

NOTE: Values will auto-save.

 

Figure 27 

Figure 28 

View From Floor

Union Assembly 

Selector Mode Switches 

Содержание Norton D6001BP-38-LH

Страница 1: ...nverter 6000IN End Cap LH 6001ENLH Union Spacer 6001US Operator LAP 6021LAP Inverter 6000IN Power Supply 6000SUP Power Module Sub assembly 6001PM Closer Assembly 7500LAP Main Arm and Rod 6030 1W Adjus...

Страница 2: ...cal Data 4 Prepare Frame and Doors 5 Install Operators 8 Install Track and Arm 11 Adjustments 12 Power Operators 13 Sync Operators 14 Finalize Installation 15 General Electrical Information 15 Wiring...

Страница 3: ...thers required Closing When the hold open time has elapsed the door closer will close the door automatically The door will slow to low speed at latch before it reaches the fully closed position The do...

Страница 4: ...ased on 1 8 gap between door and frame All dimensions are given in inches DO NOT scale drawings Thickness recommended for reinforcements in hollow metal doors and frames is charted This template infor...

Страница 5: ...r shimming is required Failure to mount units properly can result in improper function of operator or inability to snap on covers 3 Mark center of opening on frame header between jambs 4 Using chart m...

Страница 6: ...ing backplate as template mark conduit slot and Dim D mounting hole Figure 5 NOTE Dim D should be 5 16 up from bottom of frame header if backplate is properly aligned 7 Drill hole for mounting screw a...

Страница 7: ...t to properly secure top edge of backplate Use of blocking supplied by others or shims provided to fill gap between backplate and wall above header is HIGHLY recommended Material must comply with loca...

Страница 8: ...LAP so spring tube of closer is pointed toward closest hinge edge of frame Slide each LAP over two 2 screws and tighten Figure 11 NOTE When properly oriented spring tube is at bottom on left hand bac...

Страница 9: ...embly so two 2 conduit holes are at bottom and text on wire input label is legible Figure 13 2 Secure assembly to backplate using four 4 8 32 x 5 16 Phillips head screws Figure 13 WARNING BUILDING POW...

Страница 10: ...or Operator LAP 10 Pin Black Connector Operator LAP 3 Pin White Connector Power Module Sub assembly 3 Pin White Connector Power Module Sub assembly 10 Pin Black Connector Operator LAP 10 Pin Black Con...

Страница 11: ...l two 2 1 4 20 x 1 5 8 screws through each shoe and into sex bolts Figure 19 NOTE Orient shoe with short side of shoe toward hinge Figure 20 View from ceiling looking downward Short Side of Shoe Hinge...

Страница 12: ...reach nut remove Torx screw in end cap access door and slide door open When finished slide access door closed and reinsert 6 Torx flat head screw to secure door Figure 26 Adjustments A Adjust mechani...

Страница 13: ...sh up or down on joystick Figure 27 To change setting of a menu item when cursor is on that item push joystick left right to increase decrease value NOTE Values will auto save 3 seconds after adjustme...

Страница 14: ...o Single increase to Dbl Follower NOTE Dbl MasterCoord to be used when astragal or similar is attached to Master door or as a replacement for a mechanical door coordinator Once set Master Figure 29 Un...

Страница 15: ...backplate verify backplate is not warped or twisted Additional support or shimming may be required See Sections A B under Prepare Frame and Door WARNING Make sure no wiring is loose or can be caught b...

Страница 16: ...ce connected to Aux 1 is sending constant signal Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal Aux 3 Stuck Activation device connected to Aux 3 is sending constant signal...

Страница 17: ...mware Rev Single Single Door Dble Follow Dble Master Dble Mast Coord Single Set on Single for a single stand alone door Dble Follow for Follower door on pair of doors Dble Master for Master door on a...

Страница 18: ...Function with Switches For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed Fail Secure Electric Strike 24VDC Wiring For Master Follow...

Страница 19: ...to NC For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed and latched Activating switch will energize exit device and door will automa...

Страница 20: ...osed Activating switch will open door Door will remain in indefinite hold open until activating switch is activated a second time causing door to close Change Factory Pre Wiring to Illustration Below...

Страница 21: ...t be used to connect inverters Doors are normally closed and latched Fire Alarm activation will retract exit device latch bolt and door operator will open door Door will remain open until the Fire Ala...

Страница 22: ...ed Activating wireless switch or hand held wireless transmitter will open door Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causin...

Страница 23: ...re normally closed and latched Activating outside door switch will open outside door After vestibule time delay has elapsed a signal will be sent to inside door which will open Activating inside door...

Страница 24: ...eps 1 4 Hand Held Configuration depress push plate to activate transmitter 4 Attach transmitter to inside of electrical box and complete installation Removing Transmitter Code s Single Transmitter Cod...

Страница 25: ...will close after hold open time delay has elapsed If door is closed and 585 Presence Detector senses something in opening door will not open If door is at open position and 585 Presence Detector sens...

Страница 26: ...oller screen If DT is set to Standard this is normal Door Toggle mode and will not work with Presence Sensor set to Stall door closing will stall until presence not sensed set to Return Open presence...

Страница 27: ...ing When door reaches open position door drifts further open Decrease Hold Speed on controller see page 17 until door stops drifting When door reaches open position door bounces Decrease Slow Speed on...

Страница 28: ...d Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group Inc is prohibited 80 9360 1030 020 Rev 6 11 20 D 2 7 60 1 reveal 6 8 175 max...

Отзывы: