44
EN
Outputs
External door handle operated
With a lock with split handle follower: the output
switches when the outer door
handle is actuated.
Internal door handle operated
With a lock with split handle follower: the output switches when the inner door
handle is actuated.
With a lock with non-split handle follower: the output switches when a door
handle is actuated.
BMA – fire alarm
The output switches when there is a voltage at the “BMA” input.
No electrical
voltage
means the fire alarm system reports an alarm or is down.
Door handle coupled
With a lock with split handle follower:
the output relay
switches when the outer door handle is coupled.
Door drive control
A swing door drive can be activated via this output.
The output switches when the lock is completely unlocked and the door can be
opened.
Unlocked
The output switches when all bolts and, if applicable, the latch bolts are retracted
and all electric strikes are unlocked.
Locked
The output switches if the integrated monitoring contact reports
door closed
and
· all bolts are extended in a motorised lock or
· all bolts are barred in a coupling lock and the door handle is uncoupled.
Door closed
The output switches if all monitoring contacts report
door closed
.