Rotary switch – configuration of inputs and outputs
Position
Function
Inputs
IN1
IN2
1
Handle control/monitoring
External release
External door contact
*1)
2
Cylinder handle control
External release
External door contact
*1)
3
Access control/cylinder handle control External release
External door contact
*1)
4
Access control motorised lock
External release
External door contact
*1)
5
Access control/cylinder motorised lock External release
External door contact
*1)
6
Cylinder/BMA motorised lock
External release
External door contact
*1)
7
Cylinder motorised lock
External release
External door contact
*1)
8
No function assigned
Tab. 1: Configuration of inputs via the rotary switch (access control)
Position
Function
Outputs
REL1
REL2
1
Handle control/monitoring
Locked
Internal door handle
operated
2
Cylinder handle control
Locked
Cylinder operated
3
Access control /
cylinder handle control
Locked
Cylinder without internal
door handle
4
Access control motorised lock
Locked
Internal door handle
operated
5
Access control /
cylinder motorised lock
Locked
Cylinder without internal
door handle
6
Cylinder/
BMA motorised lock
Locked
Cylinder operated
7
Cylinder motorised lock
Locked
Cylinder operated
8
No function assigned
Tab. 2: Configuration of outputs via the rotary switch (access control)
*1)
External monitoring contact (or insert monitoring contact bridge)
0 1 2
3
4
5
6 7
8
9 A
B
C
D
E
F
0 1 2
3
4
5
6 7
8
9 A
B
C
D
E
F
Inputs and outputs
Содержание N5951000PILL000
Страница 25: ...25 DE ...
Страница 49: ...49 EN ...
Страница 73: ...73 FR Accessoires entretien garantie élimination ...
Страница 97: ...97 IT ...
Страница 121: ...121 NL Toebehoren onderhoud garantie afvalverwijdering ...
Страница 122: ...122 NL ...
Страница 123: ...123 NL ...