52
EN
Assembly
Warning!
Inspect for damage:
Damage to cables can lead to electric shock. Damage to metal parts can lead to
injuries. A damaged lock is a safety risk.
· Never put a damaged device into operation. Never use damaged cables or plug connections.
· Always inspect the packaging and the lock for damage.
Always comply with local building regulations and provisions:
Always comply with all building regula-
tions when assembling the lock and electrical connection. Comply with the instructions of the door manu-
facturer.
At tention!
Material damage caused by working on the door leaf:
Dismantle and remove the lock when working on
the door leaf, for example when drilling or milling.
· Only use the factory-made drill holes for attaching the door fittings
· Dismantle and remove the lock before working on the door leaf, for example when drilling or milling.
Functional impairment caused by faulty milling of the lock recess:
It must be possible to insert the lock
without force and screw it in place without distortion.
· Mill the lock recess according to the lock case dimensions.
Damage caused by dirt:
Contamination damages the lock.
· Clean the lock recess and all drill holes by blowing out or vacuuming before installation.
Impaired function caused by distorted installation:
All bolts must be able to close without transverse
loading.
· Install the lock, all bolts and accessories (strike plate, fittings, lever handle) without distortion.
Material damage caused by forced insertion of the latch pin into the lock follower:
It must be possible
to simply push the latch pin of the door handle into the lock follower.
· Do not use any tools to push the latch pin into the lock follower.
Impaired function caused by door handle not moving freely:
Install the lock so that the latch pin and
the lock follower are aligned.
Danger of destruction by construction key:
Using a construction key can destroy the lock. The lock func-
tion is then no longer guaranteed.
· Use a suitable locking cylinder to operate the lock.
Comply with the power supply tolerances:
Exceeding or falling below the tolerance limits will cause
damage and malfunction.
· Measure the lock to verify that the operating voltage is within the stated tolerance limits during nominal
current consumption.
!
A
Assembly
Содержание MSL 15544PE-SV
Страница 19: ...19 Montage DE Abb 6 Sachschaden vermeiden 1 2 1 2 max 150 N ...
Страница 23: ...23 Montage DE Schloss manuell prüfen Abb 9 Manuelle Funktionsprüfung 1 2 3 4 5 ...
Страница 24: ...24 DE Montage ...
Страница 53: ...53 Assembly EN Fig 6 Prevent material damage 1 2 1 2 max 150 N ...
Страница 57: ...57 Assembly EN Checking the lock manually Fig 9 Manual function testing 1 2 3 4 5 ...
Страница 58: ...58 EN Assembly ...
Страница 87: ...87 Montage FR Fig 6 Éviter les dommages matériels 1 2 1 2 max 150 N ...
Страница 91: ...91 Montage FR Contrôle manuel de la serrure Fig 9 Contrôle fonctionnel manuel 1 2 3 4 5 ...
Страница 92: ...92 FR Montage ...
Страница 121: ...121 Montaggio IT Fig 6 Evitare danni materiali 1 2 1 2 max 150 N ...
Страница 125: ...125 Montaggio IT Verificare manualmente la serratura Fig 9 Verifica di funzionamento manuale 1 2 3 4 5 ...
Страница 126: ...126 IT Montaggio ...
Страница 138: ...138 IT Problema causa soluzione ...
Страница 146: ...146 DE EN FR IT Abbildungen Illustrations Illustrations Figure ...
Страница 147: ...147 Abbildungen Illustrations Illustrations Figure DE EN FR IT ...