Securitron Magnalock Corp.
Tel 775.355.5625
550 Vista Boulevard
Fax 775.355.5633
Sparks, NV 89434
www.securitron.com
© Copyright, 2008, all rights reserved
PN# 500-10420
Page
1
Rev. E, 05/08
ASSA ABLOY, the global leader
in door opening solutions
MAGNALOCK MODELS M32, M62 AND M82B
INSTALLATION INSTRUCTIONS
1. INTRODUCTION
The Securitron Magnalock family represents the state of the art in electromagnetic locking.
There are three (3) models with operational electrical characteristics including mounting
configuration options addressed in this manual.
The
BondSTAT
“B” Magnalock Series, Bond Sensor, monitors the magnetic field. An internal
sensor activates a SPDT dry contact relay connection designed for interface to access control
and/or alarm systems for reporting the status of the Magnalock.
(Section 5.2.4)
The
DPS
“D” Magnalock Series, Door Position Sensor, is activated by a special magnetic strike
armature assembly. The isolated SPDT reed switch, with an internal resettable protection device,
is designed for interface to access control and/or alarm system for door status.
(Section 5.2.4)
2. SPECIFICATIONS
MODEL
M32 M62
M82B
Holding Force
600 Lbs [272 kg]
1200 Lbs [544 kg]
1800 Lbs [816 kg]
Dimensions: Length
8" [203mm]
8" [203mm]
12" [305mm]
Height
1.88" [48mm]
3" [76mm]
3" [76mm]
Depth
1.6" [41mm]
1.75" [44mm]
1.75" [44mm]
Dual Voltage
12/24 Volts DC
Current: @ 12 VDC
300mA
250mA
350mA
@ 24 VDC
150mA
150mA
200mA
Capacitance: @ 12 VDC
6.8 mF
44 mF
44 mF
@ 24 VDC
6.8 mF
11 mF
11 mF
BondSTAT Rating
Voltage: 30 VDC (Maximum) ~ Current: 1 Amp (Maximum)
DPS Rating
Voltage: 30 VDC (Maximum) ~ Current: 125 mA (Maximum)
3. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, the lock assembly should include the following items:
Figure 1
Magnalock
Sex Bolt
Strike Plate
Hardware Pack
Содержание M32
Страница 15: ...PN 500 10420 Page 15 Rev E 05 08 ...