PN#
500-10420
Page
7
Rev. E, 05/08
GATE STYLE OPERATIONS AND INSTALLATION TECHNIQUES
Figure 9
5.3
ELECTRICAL INSTALLATION
5.3.1
General Characteristics
The Magnalock is a low current load device using specialized internal circuitry. The normal
characteristic of an inductive load, such as inductive kick-back, is not present. See
Section 2
for
more information.
5.3.2
Electrical Standards
DC voltage, full-wave rectified, must be provided for proper operation of the Magnalocks. The
red wire re12VDC or +24VDC, and the black wire, 0 Volts (negative). If the lock is
connected with reverse polarity, it will not operate. The M32, M62 and M82B Magnalocks are
auto sensing dual voltage locks. The Magnalock circuit design will automatically select the proper
operational conditions for the applied voltage. See
Section 2
for more information.
5.3.3
Poor Release Characteristics
The Magnalock is designed with quick release circuitry. Wiring errors may cause a Magnalocks to
release slowly.
Figure 10
illustrates a parallel installation of a resistive load (correct).
Figure
11
illustrates a parallel reverse diode (incorrect).
Figure
10
Figure
11
5.3.4
Sensor Ranges (ELECTRICAL)
The “B” version monitoring system is also voltage sensitive. The specified voltage ranges must
be properly applied. Refer to
Section 2
for the recommended operating voltage ranges.
Содержание M32