INSTALLER - SETUP AND CONFIGURATION
BACKLIT HOME BUTTON
When configuring your network, Actuators are loaded into groups known as Zones.
Multiple Zones are available. Each actuator can only be allocated to one Zone.
BASIC OPERATING PRINCIPLE
Ensure all wiring connections are complete before powering up.
Ideally the Actuators should be powered up before the Keypads. This ensures the Keypads register
all Actuators on the network. If powering up the system is not possible in this manner, and Actuators have not been
recognized, press Restart Keypad in the Setup page. Then proceed to Zone Setup to allocate the Actuators
that have not previously registered.
POWERING UP THE SYSTEM
Once all Actuators are registered the system will proceed to a calibration screen.
Press Calibrate Actuators. All Actuators will move open and close twice.
If a warning is displayed stating ‘Window Obstructed’ this means that an Actuator has performed a safety stop.
Locate this window. Press Home and then Close All. Only the obstructed window will close.
Fix the obstruction. Then press Calibrate Actuators to continue.
CALIBRATION – Ensure there are no obstructions blocking the windows