background image

17

Using the System

The PIRs have a built-in sleep timer to save
battery power. If there is no movement in front
of the PIRs for 1 minute, the PIRs will become
‘ready to signal’ and movement will now be
reported. The PIRs will sleep for 1 minute after 
reporting.

Any movement detected in sleep time will not be
reported and will extend the sleep period by a
further 1 minute.

i

Away Arm

Arming the System

1

 When the system is disarmed (alarm off), press the 

arm key on the control unit, keypad or keyfob.

2

 The control unit will start its countdown.

3

 When the exit delay time is up, the control unit will 

sound a long beep. The siren will beep once and 
the strobe will flash once after the exit delay has 
expired. ‘Alarm on’ will be displayed on the screen 
and the system is now in away armed.

4

 If there are faults within the system, i.e. the tamper 

switch of a sensor left opened, the user will not be 
able to arm the system with a single press. The 
user can use the control panel, keypad and keyfob 
to force arm the system by pressing arm twice.

Stopping the Exit Delay by Disarming

1

 Press the disarm key on the keyfob or press the 

disarm key followed by a PIN code on the control 
unit and keypad.

2

  ‘Alarm off’ will be displayed on the screen and the 

system will return to disarmed mode.

Extending the Exit Delay

• The exit delay time can be extended during the 

exit delay period by pressing the arm button on 
the keypad or keyfob. Each time the arm button 
is pressed, the delay time starts counting from the 
beginning.

Alarm Activation

• If any Door/Window contact or PIR sensor set to 

entry or away entry is triggered, the entry timer will 
be started. If the entry timer is allowed to expire 
the alarm will be activated.

• If other sensors not set to entry or away entry is 

triggered, the alarm will be activated immediately.

Disarm

 

Disarming the System

1

 Press the disarm key on the keyfob or press the 

disarm key followed by a PIN code on the control 
unit and keypad.

• The keyfob will only disarm the system during 

entry time after an entry or away entry door/
window contact or PIR has been triggered.

2

  The control unit will sound two beeps. The siren 

will beep twice and the strobe will flash side to 
side. ‘Alarm off’ will be displayed on the screen 
and the system is now disarmed.

3

  The control panel will lock out for 5 minutes with 5 

beeps if the PIN code had been entered incorrectly 
for five times.

Home Arm

The home mode allows the home to be partially 
armed so that no one can get inside without first 
disarming the system. However, the person inside 
the house can move freely around without triggering 
the alarm. Home mode is usually used to protect the 
ground floor when you are upstairs in bed.

Arming in Home Mode

1

 When the system is disarmed (Alarm off), press 

the home arm key on the control unit, keypad or 
keyfob.

2

 The control unit will start its countdown.

3

 When the exit delay time is up, the control unit 

will sound three short beeps. The siren will beep 
once and the strobe will flash once after the exit 
delay has expired. ‘Home’ will be displayed on the 
screen and the system is now home armed.

4

 If there are faults within the system, i.e. the tamper 

switch of a sensor left opened, the user will not be 
able to arm the system with a single press. The 
user can use the control panel, keypad and keyfob 
to force arm the system by pressing arm twice.

Extending the Exit Delay

• The exit delay period can be extended in a similar 

manner as described in Away Arm.

Alarm Activation

• If any door/window contact or PIR sensor set to 

entry is triggered, the entry timer will be started. If 
the entry timer is allowed to expire the alarm will 
be activated.

• Home omit and away entry sensors will be 

ignored.

• If other sensors not set to home omit, entry 

6

Arm and disarm the system and practice using it. Trigger the alarm by arming the system and
opening protected door/windows and walking past PIRs. Now is the time to show the rest of
the family how simple it is to use.

Содержание HSA6500

Страница 1: ... s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required The external Siren is extremely loud please ensure you replace the cover and retreat to a safe distance before testing The dialling SMS facilities must only be used with persons who have cons...

Страница 2: ...e operation Extend The System Extend the system in the future to increase your security or as your needs change For example add extra PIR detectors and extra door window contacts Choosing Location To minimise interference avoid locating devices close to metal framework glass electrical appliances especially wireless devices and electric cables Please note that the present of high density material ...

Страница 3: ...ble Do not aim a PIR at this door or window PIR movement detector Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 9 and 2 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not point directly at sources of...

Страница 4: ...e backup battery duration the backlights will be switched off during mains power failure Remove the Sim card Power switch cover and switch the internal battery to on Insert a standard size GSM sim card not provided and replace the back cover Please ensure the sim card is not pin protected 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren tamper switch unnecessa...

Страница 5: ...move the cover and insert the 3 AAA alkaline batteries as shown The Tx LED will flash briefly while components initialise Please note the Home button on the operating panel and the jumper switch inside do not move have no function on this model Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the...

Страница 6: ...t date time ok Press OK 3 to continue Set date press ok when done ok Press OK 3 to continue date setting 01 jan pqOK Set the current month using the p q key Press OK 3 to confirm setting Set the day using the p q key Press OK 3 to confirm setting After setting the day it will now prompt you to set the time Set the current time using the p q key Press OK 3 to confirm the hour follow by setting the ...

Страница 7: ...e press the test learn button on all your accessories please add Siren later one at a time Every time a button is pressed the screen will prompt the device and you will need to press OK on the panel to acknowledge add It would then be reverted to the Exit Setup Repeat setup screen Please press the learn button on the next device and repeat the above steps Please ensure all the devices are added on...

Страница 8: ...the learn test button the control unit should respond with a chime If the sensor signal reached the control unit the screen will briefly display dc zone01 b 6 Note this screen shot is use as example only The radio signal strength is shown by a number on the upper right 6 in this case this number ranges from 1 to 9 strongest Where possible please ensure sensor shows 3 or above for optimal performan...

Страница 9: ... LED lights up it implies the two items are within range i Mounting using adhesive pads Clean the mounting surface with a suitable degreaser agent Please note that some surface or environment i e exposure to Sunlight maybe unsuitable for this mounting method Please use screw mounting in these cases Mounting using screws and wall plugs Loosen the bottom screw and open the door window contact Knock ...

Страница 10: ...ing is disabled by default If you need Home arming function see Chapter 5 Home arm set i All accessories were pre set to entry attributes When the system is first armed user will have 30 seconds to exit the building System will ignore any sensors triggering in this duration If the system is already armed triggering any sensors will cause an entry countdown to begin When the alarm is triggered the ...

Страница 11: ...t is selected you will be given 4 different options Sensor Test External Siren test Panel Siren test and Phone alert Sensor Test three beeps will sound during a screen self test This allows you to test the system without causing an alarm To test if the control panel is receiving a signal do one of the following depending on the device 1 Press Arm on the keypad 2 Press the test learn button on the ...

Страница 12: ...te Controller emergency Button Help Button Remote Keypad dual emergency buttons Control Unit dual key emergency 1 and 3 keys Zone Type List Burglar When the system is in home or away armed mode and a burglar device is triggered a burglar alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be igno...

Страница 13: ...am the siren select Program siren under the Devices menu The following items are available in this menu Learn Siren Siren Tamp On Siren Tamp Off Confirm On Confirm Off Entry Snd On Entry Snd Off Learn Siren The control unit requires that at least one device is programmed into the system before the siren is added Put the siren into learn mode by pressing the learn button on the siren The siren LED ...

Страница 14: ...sing 3 You will now be asked to name the PIN code The new code is now programmed P can be used to correct entry errors pressing P repeatedly will return you to the PIN code list User 1 code can only be changed and cannot be erased All other codes can be erased by selecting them and pressing 3 An error message will be shown if either an incorrect repeat code is used or a duplicate code is entered f...

Страница 15: ...via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit to report over the telephone line 1 Use the pq keys to select a number from the list 2 Press 3 to confirm If there was a number already stored then you will be asked to change the number if the slot was empty you will be asked to enter ...

Страница 16: ... Periodic SMS GSM signal SMS Keyword Reset GSM Periodic SMS Use this feature to avoid pre paid sim card credit expiring The credit in a pre paid GSM sim card PAYG often expires after 90 days of inactivity please check with your provider This option allows you to set an automatic SMS period between 10 days to 180 days By sending out SMS periodically it will keep the sim card live and avoid credit e...

Страница 17: ...or press the disarm key followed by a PIN code on the control unit and keypad The keyfob will only disarm the system during entry time after an entry or away entry door window contact or PIR has been triggered 2 The control unit will sound two beeps The siren will beep twice and the strobe will flash side to side Alarm off will be displayed on the screen and the system is now disarmed 3 The contro...

Страница 18: ...iated the control unit will wait for 15 seconds before dialling the preset phone numbers For voice call the control panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the mes...

Страница 19: ... 1 hour after which it will automatically arm again If longer is needed to fit the siren then simply repeat the steps above Leave the control unit in programming mode to stop the system responding to tampers If the control unit automatically times out re enter programming mode again i Enabling the system tamper After mounting the siren and detectors please enable the system tamper by 1 Press the m...

Страница 20: ...d after an entry or away entry sensor is activated in the entry period Keypad Keypad code changing and setting The keypad comes with a factory default code of 0000 This code will need to be changed to the same code used in the control panel for the keypad to disarm the system To do this you will need to 1 Press the Panic button A key followed by factory default keypad code 0000 2 The LED will now ...

Страница 21: ...riod If the smoke density is still over the alarm threshold then the smoke detector will remain in an alarm condition and it will repeat the local fire alarm with a radio fire alarm signal to the control unit Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime will send a radio test signal to the contro...

Страница 22: ...disarmed take care not to confuse the two different conditions PIR battery change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Put control unit into programming mode to prevent a tampered alarm 2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries 3 Insert new alkaline batteries observing correct pol...

Страница 23: ...ress a number key and check that the LED lights If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Help button battery change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new CR2032 coin cell taking ...

Страница 24: ...w it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing directly at windows PIR LED flashes Batteries are low or the tamper switch is disturbed Check that the tamper switch spring i...

Страница 25: ...ser Pincode followed by pressing 3 Stay in the programming menu Then disconnect the relevant sensor and replace batteries If the control panel times out and returns to Alarm off please follow the above steps again and repeat the process _____________________________________________ Complete Reset Procedure Reset to factory default setting The control panel can clear all programmed parameters by th...

Страница 26: ...__________________ Jamming Interference detection User can enable Jamming interference detection should they feel it is a risk Detection via control panel From the panel s menu system select Adv Setting Jamming Det Enable Detection via External Siren Open up the siren Disable tamper first see earlier section and switch the Dip Switch 2 to On position Enabling these features increases the likely ho...

Страница 27: ...ry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action ...

Страница 28: ...mming detection Power supply 6V 4 x D alkaline cells 3 years typical service life Passive infra red PIR Detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window co...

Страница 29: ...HSA6060 HSA6080 HSA6090 HSA6091 HSA6500 HSA3045 HSA3070 Date 07 10 14 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 1 1 2006 04 EN 301 489 1 V1 6 1 2004 12 EN 301 489 3 V 1 4 1 2002 08 EN 60 950 2001 A11 corrigendum 2004 ...

Страница 30: ...creen below Panel Name Please give your panel a name Panel SIM The mobile number of your alarm panel SIM card PIN code Your alarm panel PIN code SMS Keyword Default is PROG You can change this Keyword from the panel option GSM setting SMS Keyword Once you have confirmed this setting select the panel and enter the main dashboard Please note that this app does not hold status information of your ala...

Страница 31: ...etting page 14 Please note that the parameters shown does not reflect your actual alarm settings To confirm this setting press Save to send an SMS command to the panel Report Settings This menu has a list of 6 telephone numbers notify via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit t...

Страница 32: ...D alkaline cells 3 years typical service life Passive infra red PIR detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled...

Отзывы: