background image

15

Alarm Length

The siren (both external and built-in) will sound when 
an alarm is activated. The length of the alarm can be 
set from 1 to 15 minutes in 1 minute increments with 
this setting.

• 3 minutes is the factory default.

C.U. Siren

You can disable the control unit’s built-in siren with 
this setting.

• Siren on is the factory default.

Jamming Det

Enable or disable Jamming/Interference detection on 
the control panel. Confirmed by pressing the 

3

 key. 

Default setting is Disable (recommended).

KF Entry

When selected as Off, user must first trigger an entry 
sensor before the keyfob can disable the system. 
Please select On if you wish to disarm the system 
without first triggering an entry sensor. 

• KF Entry On is the factory default.
• If the Keyfob’s Panic button is triggered, the 

same keyfob cannot be use for disarming the siren.

Time

The control unit uses a 24 hour clock.  The time 
is set by using the 

pq

 keys and confirmed by 

pressing the 

3

 key.

Date

The day and month are set by using the 

pq

 keys 

and confirmed by pressing the 

3

 key.

Final Door

If this is turned On, a system counting down under 
the full arm mode will immediately arm when user 
exit and triggers the Door contact’s close position 
(Applies to door contact with “entry” attribute only). 

• Final Door Off is the factory default.

Tel. Settings

This menu allows you to program up to 3 telephone 
numbers, record an address message and place 
test calls, The following items can be selected.

• Tel. Numbers
• Rec. Msg
• Test Report

Tel. Numbers

This menu has a list of 6 telephone numbers (notify 
via voice dial or SMS).  These numbers are dialled/
SMS in order, a maximum of 20 digits per number 
can be stored.  Only one number is required to 
enable the control unit to report over the telephone 
line.

1

 Use the 

pq

 keys to select a number from the list.

2

 Press 

3

 to confirm. If there was a number already 

stored then you will be asked to change the 
number, if the slot was empty you will be asked to 
enter a new number, confirm by pressing 

3

.

3

 Enter your phone number and confirm by  

pressing 

3

. Errors can be corrected by pressing 

P

 to backspace, pressing 

P

 repeatedly will take 

you back the telephone number list. Telephone 
numbers can be deleted in the same manner.

4

 Once a number is entered, you will be ask whether 

to use voice or SMS reporting. Please note 
that SMS reporting can only work with mobile 
numbers. If you select SMS reporting, it will further 
ask you what type of event should trigger a report. 

Rec. Msg

This menu allows the recording of your message.  
The maximum length of message is 10 seconds 
which is ample for most messages, when recording 
remember to speak clearly and slowly into the 
microphone.

1

 Press 

3

 and you will be either asked to record a 

new message or change an old one.

2

 Press  

3

 again and follow the on screen 

instructions.  When you finish recording remember 
to press 

to stop recording. If you go over the 

10 second recording time (indicated by a beep) 
just repeat the recording procedure again taking 
care not to go over the 10 second time limit. The 
recording is complete.

Test report

This menu allows you to test the telephone reporting 
feature. 

• Please check with the call recipients before making 

a test call.

• Ensure that the sim card is inserted and working. 

The sim card should not have pin code protection.

Содержание HSA6500

Страница 1: ... s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required The external Siren is extremely loud please ensure you replace the cover and retreat to a safe distance before testing The dialling SMS facilities must only be used with persons who have cons...

Страница 2: ...e operation Extend The System Extend the system in the future to increase your security or as your needs change For example add extra PIR detectors and extra door window contacts Choosing Location To minimise interference avoid locating devices close to metal framework glass electrical appliances especially wireless devices and electric cables Please note that the present of high density material ...

Страница 3: ...ble Do not aim a PIR at this door or window PIR movement detector Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 9 and 2 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not point directly at sources of...

Страница 4: ...e backup battery duration the backlights will be switched off during mains power failure Remove the Sim card Power switch cover and switch the internal battery to on Insert a standard size GSM sim card not provided and replace the back cover Please ensure the sim card is not pin protected 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren tamper switch unnecessa...

Страница 5: ...move the cover and insert the 3 AAA alkaline batteries as shown The Tx LED will flash briefly while components initialise Please note the Home button on the operating panel and the jumper switch inside do not move have no function on this model Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the...

Страница 6: ...t date time ok Press OK 3 to continue Set date press ok when done ok Press OK 3 to continue date setting 01 jan pqOK Set the current month using the p q key Press OK 3 to confirm setting Set the day using the p q key Press OK 3 to confirm setting After setting the day it will now prompt you to set the time Set the current time using the p q key Press OK 3 to confirm the hour follow by setting the ...

Страница 7: ...e press the test learn button on all your accessories please add Siren later one at a time Every time a button is pressed the screen will prompt the device and you will need to press OK on the panel to acknowledge add It would then be reverted to the Exit Setup Repeat setup screen Please press the learn button on the next device and repeat the above steps Please ensure all the devices are added on...

Страница 8: ...the learn test button the control unit should respond with a chime If the sensor signal reached the control unit the screen will briefly display dc zone01 b 6 Note this screen shot is use as example only The radio signal strength is shown by a number on the upper right 6 in this case this number ranges from 1 to 9 strongest Where possible please ensure sensor shows 3 or above for optimal performan...

Страница 9: ... LED lights up it implies the two items are within range i Mounting using adhesive pads Clean the mounting surface with a suitable degreaser agent Please note that some surface or environment i e exposure to Sunlight maybe unsuitable for this mounting method Please use screw mounting in these cases Mounting using screws and wall plugs Loosen the bottom screw and open the door window contact Knock ...

Страница 10: ...ing is disabled by default If you need Home arming function see Chapter 5 Home arm set i All accessories were pre set to entry attributes When the system is first armed user will have 30 seconds to exit the building System will ignore any sensors triggering in this duration If the system is already armed triggering any sensors will cause an entry countdown to begin When the alarm is triggered the ...

Страница 11: ...t is selected you will be given 4 different options Sensor Test External Siren test Panel Siren test and Phone alert Sensor Test three beeps will sound during a screen self test This allows you to test the system without causing an alarm To test if the control panel is receiving a signal do one of the following depending on the device 1 Press Arm on the keypad 2 Press the test learn button on the ...

Страница 12: ...te Controller emergency Button Help Button Remote Keypad dual emergency buttons Control Unit dual key emergency 1 and 3 keys Zone Type List Burglar When the system is in home or away armed mode and a burglar device is triggered a burglar alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be igno...

Страница 13: ...am the siren select Program siren under the Devices menu The following items are available in this menu Learn Siren Siren Tamp On Siren Tamp Off Confirm On Confirm Off Entry Snd On Entry Snd Off Learn Siren The control unit requires that at least one device is programmed into the system before the siren is added Put the siren into learn mode by pressing the learn button on the siren The siren LED ...

Страница 14: ...sing 3 You will now be asked to name the PIN code The new code is now programmed P can be used to correct entry errors pressing P repeatedly will return you to the PIN code list User 1 code can only be changed and cannot be erased All other codes can be erased by selecting them and pressing 3 An error message will be shown if either an incorrect repeat code is used or a duplicate code is entered f...

Страница 15: ...via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit to report over the telephone line 1 Use the pq keys to select a number from the list 2 Press 3 to confirm If there was a number already stored then you will be asked to change the number if the slot was empty you will be asked to enter ...

Страница 16: ... Periodic SMS GSM signal SMS Keyword Reset GSM Periodic SMS Use this feature to avoid pre paid sim card credit expiring The credit in a pre paid GSM sim card PAYG often expires after 90 days of inactivity please check with your provider This option allows you to set an automatic SMS period between 10 days to 180 days By sending out SMS periodically it will keep the sim card live and avoid credit e...

Страница 17: ...or press the disarm key followed by a PIN code on the control unit and keypad The keyfob will only disarm the system during entry time after an entry or away entry door window contact or PIR has been triggered 2 The control unit will sound two beeps The siren will beep twice and the strobe will flash side to side Alarm off will be displayed on the screen and the system is now disarmed 3 The contro...

Страница 18: ...iated the control unit will wait for 15 seconds before dialling the preset phone numbers For voice call the control panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the mes...

Страница 19: ... 1 hour after which it will automatically arm again If longer is needed to fit the siren then simply repeat the steps above Leave the control unit in programming mode to stop the system responding to tampers If the control unit automatically times out re enter programming mode again i Enabling the system tamper After mounting the siren and detectors please enable the system tamper by 1 Press the m...

Страница 20: ...d after an entry or away entry sensor is activated in the entry period Keypad Keypad code changing and setting The keypad comes with a factory default code of 0000 This code will need to be changed to the same code used in the control panel for the keypad to disarm the system To do this you will need to 1 Press the Panic button A key followed by factory default keypad code 0000 2 The LED will now ...

Страница 21: ...riod If the smoke density is still over the alarm threshold then the smoke detector will remain in an alarm condition and it will repeat the local fire alarm with a radio fire alarm signal to the control unit Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime will send a radio test signal to the contro...

Страница 22: ...disarmed take care not to confuse the two different conditions PIR battery change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Put control unit into programming mode to prevent a tampered alarm 2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries 3 Insert new alkaline batteries observing correct pol...

Страница 23: ...ress a number key and check that the LED lights If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Help button battery change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new CR2032 coin cell taking ...

Страница 24: ...w it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing directly at windows PIR LED flashes Batteries are low or the tamper switch is disturbed Check that the tamper switch spring i...

Страница 25: ...ser Pincode followed by pressing 3 Stay in the programming menu Then disconnect the relevant sensor and replace batteries If the control panel times out and returns to Alarm off please follow the above steps again and repeat the process _____________________________________________ Complete Reset Procedure Reset to factory default setting The control panel can clear all programmed parameters by th...

Страница 26: ...__________________ Jamming Interference detection User can enable Jamming interference detection should they feel it is a risk Detection via control panel From the panel s menu system select Adv Setting Jamming Det Enable Detection via External Siren Open up the siren Disable tamper first see earlier section and switch the Dip Switch 2 to On position Enabling these features increases the likely ho...

Страница 27: ...ry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action ...

Страница 28: ...mming detection Power supply 6V 4 x D alkaline cells 3 years typical service life Passive infra red PIR Detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window co...

Страница 29: ...HSA6060 HSA6080 HSA6090 HSA6091 HSA6500 HSA3045 HSA3070 Date 07 10 14 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 1 1 2006 04 EN 301 489 1 V1 6 1 2004 12 EN 301 489 3 V 1 4 1 2002 08 EN 60 950 2001 A11 corrigendum 2004 ...

Страница 30: ...creen below Panel Name Please give your panel a name Panel SIM The mobile number of your alarm panel SIM card PIN code Your alarm panel PIN code SMS Keyword Default is PROG You can change this Keyword from the panel option GSM setting SMS Keyword Once you have confirmed this setting select the panel and enter the main dashboard Please note that this app does not hold status information of your ala...

Страница 31: ...etting page 14 Please note that the parameters shown does not reflect your actual alarm settings To confirm this setting press Save to send an SMS command to the panel Report Settings This menu has a list of 6 telephone numbers notify via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit t...

Страница 32: ...D alkaline cells 3 years typical service life Passive infra red PIR detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled...

Отзывы: