39
Inputs and outputs
EN
Status messages / LEDs
LEDs (Fig. 2) are used to display the statuses of the inputs and outputs (relays).
LED
Meaning
1
:
Input
illuminated It input is closed against GND
2
:
Relay (output)
illuminated The relay is activated / active
In addition, the operational availability is displayed using three LEDs.
LED 1
(red)
LED 2
(green)
Status of the IO module
–
X
IO module is online and ready for operation
flashing
flashing IO module is offline or starting up
(the automatic initialisation is running)
Fig. 2 :
LEDs on housing cover
Fire alarm
External unlocking
External door contact
Central locking
Handle inside
Key cylinder contact
Clutch monitoring
Unlocked
Locked
Door closed
Alarm / Fault
Status
N5950
no USB
D00852
Handle outside
Door operator
1
2
LED 1
LED 2
Organise products in Hi-O groups
The
Hi-O Technology™
products are assigned to two Hi-O groups via DIP switches. The products’ digital
communication is always conducted exclusively within the assigned Hi-O groups.
For instance, the locks of a double-leaf door with separate monitoring of the active and inactive leaf can be
controlled separately via two separate IO modules. One lock forms Hi-O group 0 with its IO module, while
the other one forms Hi-O group 1 with its IO module (“DIP switch”, page 42, and Fig. 8).
Содержание Hi-O Technology OneSystem N5950
Страница 29: ...29 DE...
Страница 57: ...57 Problem cause solution EN...
Страница 85: ...85 FR...
Страница 86: ...86 FR...
Страница 87: ...87 FR...