background image

5

ED3400/ED3400A Series

Installation Instructions

Surface Vertical Rod

FM361  04/20

Copyright © 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in 

part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

Installation (cont .)

Active Case

1.  Remove cover from active case chassis.
2.  Mount chassis to door as indicated in Figure 5  

and Figure 6.

3.  If installing a cylinder function, ensure hub  

pin is in correct position. (Step 3c)

Note

Active case is larger than inactive case.

Figure 7 

 

Wood: #10 x 1-1/4" 

Phillips flat head 

(Total = 4)

Metal: #10-24 x 3/4" 

Phillips flat under cut

(Total = 4)

Active case mounting screws - Actual size

Active case mounting screws - Actual size

Chassis

For ED3457A (Nightlatch) 

long end of pin faces down. Cylinder turns 180° in both directions. (Figure 8)

For ED3455A/ED3455AT (Classroom) 

long end of pin faces up. Cylinder turns 360° to the left or  

right. (Figure 9)

Cylinder 

hub

Hub pin up for 

55T function

Figure 8 

 

Figure 9 

 

Figure 5 

 

Active case side 

(away from 

door hinge)

Hinge 

side

 

Figure 6 

 

Содержание Corbin Russwin ED3400 Series

Страница 1: ...Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com WARNING This product can expose you to lea...

Страница 2: ...ss Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com TOC Table of Contents 1 Tools Required 3 2 Package Content...

Страница 3: ...s Required Measuring tape Power drill Drill bits 3 32 1 4 11 32 3 8 and 25 Taps 10 24 Screwdrivers Phillips 2 and Phillips 3 2 Package Contents This Exit Device Is Non Handed LHR Left Hand Reverse Hin...

Страница 4: ...floor and draw horizontal line for active case template 3 Align template T31207 for active case with centerline and tape 4 Using crossbar hole centers for measuring draw vertical centerline of inactiv...

Страница 5: ...is to door as indicated in Figure 5 and Figure 6 3 If installing a cylinder function ensure hub pin is in correct position Step 3c Note Active case is larger than inactive case Figure 7 Wood 10 x 1 1...

Страница 6: ...igure 10 and Figure 11 Note Active case is larger than inactive case Figure 12 Wood 10 x 1 1 4 Phillips flat head Total 4 Metal 10 24 x 3 4 Phillips flat under cut Total 4 Inactive case mounting screw...

Страница 7: ...template Note Use through bolt screws for fire rated doors 6 Ensure top latch bolt is fully extended 7 Rotate rod until upper hole see detail aligns with hole in active chassis and insert rod adjustm...

Страница 8: ...ress crossbar arm to verify top latch goes into holdback 2 If latch does not go into holdback pull out the adjustment pin Rotate top rod counterclockwise one complete turn reinsert pin and test again...

Страница 9: ...e and the following information For surface applied strikes 1 Transfer vertical centerline to floor or threshold and mark 2 Center strike on the marked line 3 Mark mounting holes If using Flush Bottom...

Страница 10: ...Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com 3 Installation cont k Covers 1 Attach covers to both case chassis and...

Страница 11: ...rews slightly 10 24 x 1 1 4 Phillips Oval Head Total 4 Rod Guide Mounting Screws Actual Size Rod Guide Mounting Screws Actual Size Wood 8 x 1 3 4 Phillips Oval Head Screw Total 4 Figure 27 m Crossbar...

Страница 12: ...ights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russw...

Отзывы: