8
ED3400/ED3400A Series
Installation Instructions
Surface Vertical Rod
FM361 04/20
Copyright © 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
Mount Bottom Rod Assembly (cont .)
6. Confirm crossbar arm is NOT in dogged position.
7. Remove bottom rod pin from active chassis and slide bottom rod into active chassis.
8. Attach bottom latch chassis to door.
Note
Use through-bolt screws for fire rated doors.
9. Ensure bottom latch bolt is fully extended.
10. Rotate rod until middle hole aligns with hole in active chassis and insert rod adjustment pin.
h
Adjustment
1. Depress crossbar arm to verify top latch goes into holdback.
2. If latch does not go into holdback, pull out the adjustment
pin. Rotate top rod counterclockwise one complete turn,
reinsert pin and test again. Continue this step until
holdback is achieved.
Notes
• If there is minimal thread engagement with top latch
chassis, use lower hole in rod to secure to active chassis.
• If rod is rotated too far into top latch, engagement with top strike
will not occur or will be minimal. Rotate rod counterclockwise for additional engagement.
i
Top Strike
1. Align top strike with holes on doorstop of frame and secure.
Note
Align thick end of strike closest to door.
2. Close door and verify engagement of top strike and latch.
Wood: #12 x 1-1/2"
Phillips Flat Head
(Total = 2)
Top strike mounting screws - Actual size
Metal: #12-24 x 1"
Phillips Flat Head
(Total = 2)
Top strike mounting screws - Actual size
Metal: #10-24 x 3/4"
Phillips Round Head
(Total = 2)
Top strike mounting screws - Actual size
Figure 21
Rod
adjustment
pin
Figure 19
Centerline
Top
strike
plate
Top latch
assembly
Figure 20