4
80-9330-3003-152 04/18
DC3210 Series Closer
Installation Instructions
A11 or A12 Heavy Duty Spring Stop Parallel Arm
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
2
Installation
1. Template
Mark door and jamb (for closer bracket and arm
brackets).
Frame Template 1A (Standard Application with
615F58 Bracket) (Figure 2)
For Deep Reveal: Frame Template 1B. (Figure 3)
For Flush Partition: Frame Template 1C. (Figure 4)
1/2
(12.7)
2-3/4
(70)
FRAME STOP
TOP OF DOOR
CL
HINGE
OR
PIVOT
DOOR
FRAME STOP
2-3/4
(70)
3/8
(9.5)
2
(50.8)
7/16
(11.1)
CLOSER
BRACKET
1
(25.4)
4-5/16
(109.5)
B
A
TYP.
1-3/8
(35)
1-1/4
(31.8)
1-1/8
(29)
3/4
(19)
REVEAL
615F58
BRACKET
615F58
BRACKET
Frame Reveals 1-7/8 to 4-5/8
(48mm to 117mm)
"
"
Reveal
D
o
o
r
615F58
BRACKET
Door Preparation is Typical for
all Frame Templates
1A, 1B, and 1C
NOTES:
• Check hand of door. (Figure 1)
• Right Hand Application Shown, Left Hand
Opposite
• Dimensions given in inches (mm).
Do Not Scale Drawing.
• Closer must be installed in a true
horizontal plane to ensure proper closer
performance.