10
Issue 2008-11-13
1004935-US-1.0
5.3.4
Kill Input
When Kill mode is activated, the door will close immediately if not already closed.
Hold open and low pass filter timers are reset.
Key impulse will activate lock when kill is activated if key impulse 0 VDC is not con-
nected to TB2:5.
When Kill mode is deactivated, the door will act according to one of the current input
statuses.
Several Kill mode inputs are possible to connect in parallel with other CSDB control
units. Connect to Kill electrical lug on first operator according to the connection dia-
gram. The second, third etc. operator is only to be connected in parallel, from terminal 5
to 5 and 6 to 6.
Kill Function is selected through the function selector FS1 (Kill Jumper).
5.3.5
Open Limit Switch
The Open Limit Switch indicates a fully open door and can be adjusted for opening
angles up to 120º.
When the Open Limit Switch is activated the motor will stop. If the open limit switch
is not activated, the motor will stop 10 seconds after an activation impulse is
received.
If the limit switch is deactivated when the door is open, the motor will restart to repo-
sition the door.
The illuminated LED indicates an activated limit switch.
Contact rating: 1A, 48 V DC, normally open.
5.3.6
Home Switch (optional)
When no home switch is installed and the open limit switch is deactivated (when the
door is closing) and no activation impulse received, a timer starts and after 6 sec. the
status will change from Close to Closed Door.
If the
optional
Home Switch is mounted, this will indicate closed door instead of the
timer.
“Opening Delay” for lock (0 to 3s) is ignored as soon as Home Switch is not activated.
“Slave Delay” (0,5s) is ignored as soon as home switch for the master is not acti-
vated.
Presence impulse is ignored when Home Switch indicates a closed door within 6 sec-
onds.
The LED indicates an activated Home Switch.