Aperio
®
Online Mechanical Installation Guide, Document No: ST-001323-B Date: 21 februari 2014
13
Aperio
®
Online
Placement options for AH15 when using other locks
When using non-cylinder locks, for example
Escutcheon locks, it is recommended that the
AH15 is mounted on any of the walls, and within a
5 meters/16 feet range from the lock in the zone
shown in the figure. Placement in the roof is not
recommended.
It is important that the communication hub is
mounted with the mounting holes vertically
aligned and as close to the lock as possible.
The following pages show typical installations
based on field experience that will give a good re-
sult for radio link quality. The colors indicate which
hubs and Aperio door locks that belong together.
The AH15 communication hub can be mounted
according to the following figure.
AH15 Communication hub installed on a wall,
with mounting holes according to marks.
Door with Aperio lock
Communication hubs should always be installed on the wall when using
non
e-cylinder locks.
Always align the mounting holes vertically when fastening.
Figure 5.
Place-
ment options for
AH15 with other
locks
< 4 m / ~ 13 f
t
< 5 m / ~ 16 f
t