Aperio
®
Online Mechanical Installation Guide, Document No: ST-001323-B Date: 21 februari 2014
47
Aperio
®
Online
Lock LED indications
The lock has three LEDs. They support an optical
scheme with red, yellow, and green. The
indication scheme is described by the figures
below:
One yellow flash
(.25 second)
One green flash
(1 sec.)
Access granted,
EAC offline or online
Five yellow flashes and
one red flash (.25 second)
Force closed in remote
open/office mode
Continuous yellow flashes
(.25 seconds every second)
Continuous red flashes
(.125 seconds every 1 sec.)
Continuous red flashes
(.25 seconds every 5 sec.)
Continuous yellow flashes
(.25 seconds every 5 sec.)
Busy blink, com hub
busy with other locks
One red flash
(1 sec.)
Access denied,
EAC online
Access denied,
EAC offline
Three red flashes
(.5 second each)
Lock mechanism is
blocked when closing
Tamper
Ten red flashes (.125 sec. each)
(Repeated every 10 sec.)
Time to replace
the battery
Error in lock,
maintenance required
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock cannot close)
2)
1)
Battery reached end
of life, lock disabled
Card access
(configurable)
Card+PIN access
(configurable)
EAC response
time
Enter PIN
One yellow flash after card,
two flashes before PIN (0.125 sec.)
1) When the lock mechanism is blocked (lock jammed) the knob must be turned/handle
released, to release the lock mechanism.
2) The “Error in lock” indication is also shown instead of the POST flashes if the battery is not
accepted as new after a power-on-reset.
Some special LED indication schemes are used during lock maintenance actions:
Five yellow flashes
(.125 second each)
Enter configuration
mode
Figure 25.
Lock normal
operation LED indica-
tion
Figure 26.
Lock hub
normal operation LED
indication