background image

 

Power Input 
(12-24V AC/DC) 

12 or 24 AC or DC. AC power can be connected 
without observing polarity requirement. Connect DC 
power with polarity as indicated. 

Output 1, Output 2 

SPDT dry contacts. Outputs can be programmed for 
latching or momentary operation. 

Egress Input 
(EG IN) 

A normally-open request to exit station can be 
connected to this terminal and ground (-). Connecting 
the terminal to ground will operated output 1 in the 
same manner as a valid user code. 

Key Active Output 
(KEY ACT) 

NPN transistor open collector output that switches to 
ground (-) for 10 seconds with each key press. Output 
rating Ic max: 100mA sink, Vc max: 24VDC. 

Duress Output 
(DU OUT) 

NPN transistor open collector output that switches to 
ground (-) after the duress code has been entered. 
Output rating Ic max: 100mA sink, Vc max: 24VDC. 

Door Position Sensor 
Input 
(DOOR SENS) 

A normally-closed contact connected to this terminal 
and ground (-) will provide a door position monitor. This 
terminal must be connected to ground (-) if not used. 
The factory installed jumper must be removed if using 
this input. 

Ground (-) 
(GND) 

System ground (-). 

Output 1 Inhibit 
(O/P 1 INHIB) 

Normally-open input terminal used in a cross wire 
connection in an interlock application. 

Interlock Control Output 
(INT. Lock) 

NPN transistor open collector output that switches to 
ground (-) for 5 seconds after entering a valid user 
code. Use this output to control a second keypad in a 
“Mantrap” application. 

Normally-closed 
Tamper 
(Tamper N.C.) 

Normally-closed output pair activated by the tamper 
switch if the keypad faceplate is removed from the 
back box. 

WIRING 

Содержание Alarm Controls KP-300

Страница 1: ...00 645 5538 www alarmcontrols com Model KP 400 is a self contained vandal resistant digital keypad This dual relay output keypad is suitable for residential industrial and commercial installations It...

Страница 2: ...ed tool 2 Pass the wire harness through the opening in the back box 3 Mount the back box to the door frame or wall 4 Make all required wiring connections to the terminal blocks 5 Place the keypad face...

Страница 3: ...put that switches to ground after the duress code has been entered Output rating Ic max 100mA sink Vc max 24VDC Door Position Sensor Input DOOR SENS A normally closed contact connected to this termina...

Страница 4: ...Programming Mode in order to access all keypad configuration settings 1 Put the keypad in Program Mode by entering the Installer Code followed by the The keypad will beep twice and the yellow LED wil...

Страница 5: ...tering the Installer Code followed by the The keypad will beep twice and the yellow LED will be on and not blinking 2 Enter 7 2 5 3 Enter to exit Program Mode The yellow LED will begin blinking To dis...

Страница 6: ...s 1 and 2 can be programmed for either momentary or latching operation Momentary operation time can be set for between 1 and 999 seconds The factory default momentary operation time is 2 seconds 1 Put...

Страница 7: ...ep twice and the yellow LED will be on and not blinking 2 Enter 8 2 1 3 Enter to exit Program Mode The yellow LED will begin blinking To return the keypad to Manual Entry Mode 1 Put the keypad in Prog...

Страница 8: ...new installer code For example if you wish to change the Installer Code to 1 2 3 4 you would enter 0 1 2 3 4 7 The keypad will beep twice indicating that the new Installer Code has been accepted 8 Ent...

Страница 9: ...DC POWER SUPPLY AC POWER CAN ONLY BE USED WITH AC POWERED ELECTRIC STRIKES MAGNETIC LOCK OR ELECTRIC STRIKE MODEL TS 2 REQUEST TO EXIT STATION OPTIONAL USE N O CONTACTS Output 2 is used to control acc...

Страница 10: ...2 REQUEST TO EXIT STATION OPTIONAL USE N O CONTACTS N C DOOR CONTACT Two keypads are required for an inter lock system If either door is open the other door will remain locked TAMPER SWITCH The Tampe...

Страница 11: ...5 Relative Humidity Non condensing Environmental Rating Conforms to IP66 Dimensions 3 125 W x 4 5 L x 1 75 to 2 5 D CODES It is recommended that the Installer Code and User Codes be noted here for ref...

Страница 12: ...KP 400 Rev E 3 14...

Отзывы: