Aspirante thermostatic power shower
8
Hot
19 mm
98 mm
26 mm
W
all
Cold
Rear edge
of
backplate
Fig.9
top
19 mm
26 mm
Cold
Hot
Area of
backplate
to remove
W
all
19 mm
34 mm
26 mm
Rear edge
of
backplate
Hot Cold
W
all
rear
Bottom
PLUMBING CONNECTIONS
Plumbing to be completed before wiring
note:
The outlet of the shower must not
be connected to any tap or fitting not
recommended by Triton Plc.
DO nOT use jointing compounds on any pipe
fittings for the installation.
When connecting pipework avoid using tight
90° elbows. Swept or formed bends will
guarantee optimum performance.
Isolate the mains water supply to the cold water
cistern. Drain the hot and cold pipes by opening
all taps.
The hot water supply can be taken from the hot
supply pipe from the cylinder, checking that it is
the first draw-off below the ventilation pipe tee
in order to minimise the effects of water draw-
off elsewhere in the house (see
fig.
).
note:
There must not be any other draw-offs
between the take-off point and the shower.
A dedicated cold water supply must be taken
directly from the cold water cistern to the
shower. This draw-off must be positioned
25 mm below the cold feed connection to the
hot water cylinder on the opposite side of the
cistern to the float operated valve (see
fig.
).
This minimises air ingress into the pipework.
Plumbing options other than those outlined
in these fitting instructions could impair the
performance. For example, if hot and cold
connections are made after draw-off points
to other outlets, (eg. washing machine, taps,
etc.) it could result in unstable flows and
temperatures should other appliances operate at
the same time.
Run the hot and cold pipework to the shower
position making sure that the pipework does not
rise above the level of water in the cold cistern
at any point to avoid air locks. under normal site
conditions 15 mm pipework will be adequate.
Decide the position of the shower. Cut the
pipework to the dimensions relevant to the
chosen direction of water entry into the shower.
Important:
for rear entry only, the supplied
elbows must be used. for ease of installation,
the backplate area adjacent to the top pipe
23.5 mm
Fig.0