Aspirante thermostatic power shower
9
inlet must be cut out, including the top left
wall fixing hole.
When fitting the elbows to incoming
pipework, check that the elbow collets are
fully engaged with the pipe.
Dimensions are shown in
fig.9
and
fig.0
.
note:
The pipe inlets are marked for hot and
cold connections – left side for hot inlet on
bottom entry
(fig.)
, but right side for hot
inlet on top or rear entry
(fig.)
.
Important:
The fittings on the inlet elbows
are the push-in type. The pipework must
be cut with a pipe cutter and all burrs and
rough edges removed from the end of the
tube. The fittings can be used with copper
and plastic pipe.
If using chrome plated copper pipe, remove
the first 25 mm of plating completely from the
connecting surfaces. If not completely removed
then the collet will not grip the pipe and under
pressure the pipe may be forced out.
note:
Pipework must be clipped or fixed to the
wall so that it cannot be moved or removed
without the aid of a tool.
note:
The pipe inlets contain filters. These
should be periodically removed and cleaned
in order to maintain the performance of the
shower. See section ‘cleaning’ on how to access
the filters.
Two factory fitted blanking plugs are fitted to the
top pipe inlets. These should be left in position if
bottom pipe entry is required. But for top or rear
pipe entry, the two plugs must be removed and
refitted into the bottom pipe inlets.
Insert the pipe removal tool supplied between
the flange of the plug and the grey collet
and lever the plug outward
(fig.)
. While
holding back on the collet, pull out each
plug by hand. When refitting the plugs in the
bottom pipe inlets, make sure that they are
pushed fully home.
Bottom
(rising)
supply
Top
(falling)
or rear
supply
Hot
side
Hot
side
Bottom
(rising)
supply
Top
(falling)
or rear
supply
Hot
side
Hot
side
Fig.
Fig.
Blanking
plug
Fig.
Important:
The inlets contain check
valves, so before completing the connection
of the water supplies to the shower flush
out the pipework to remove all swarf and
system debris that may cause damage to
internal parts. This can be achieved by
connecting a hose to the pipework and
turning on the water supplies long enough
to clear the debris to waste.