9
E N G L I S H
ASPIRCOMFORT PRO dH
2. INSTALLATION
2.1 INSTALLATION CONDITIONS
The unit must be installed based on national and local regulations governing the use of electrical devices
and based on the following indications:
• install the unit inside residential buildings with room temperature between 0°C and 45°C;
• avoid areas near sources of heat, steam, inflammable and/or explosive gases and particularly dusty areas;
• install the unit in a place that is not subject to frost (the condensation water must be discharged not frozen, at
a certain slope, using a trap);
• do not install the unit in zones with a high relative humidity rate (such as bathroom or toilet) to avoid
condensation on the external surface;
• choose a place of installation where there is enough room around the unit for the connections of the air ducts
and to perform maintenance activities;
• the consistency of the ceiling/wall/floor where the unit will be installed must be suitable for the weight of the
unit and not cause vibrations.
The room chosen for installation must have:
- air duct connections;
- 230V single-phase electrical connection
- connection for the condensation discharge
- hydraulic connection