Test report no.:
12 205 399386-000
Certificate no.:
44 780 12 399386
EC type-examination no.:
44 205 12 399386
12. Technical Data
Supply voltage
Low voltage:
U
E
24 V AC/DC
±10 %
I
E
85 mA
I
max
180mA (100ms)
Input power
: P
E-max
3 W 24 V DC
P
E-max
3 VA 24 V AC
Ensuring low
voltage (external):
125mA Medium acting fuse
125mA Flink can be used
alternatively
Terminal resistance oft the sensor
nominal value
R
nom
8,2 kΩ
upper switching point R
AO
> 12,0 kΩ
lower switching point R
AU
< 5,0 kΩ
Safety relay
Nominal current DC
DC-13 / 24 V / 2 A
Nominal current AC
AC-15 / 30 V / 2 A
Mechanical life-time
>10
6
actuations
Saftey Relais
Fuse type
M 2 A 5 x 20 glass tube
Safety relay switching times
Switching off delay
< 12 ms
(response time)
Turn-off time
500 ms (ELMON rail 32-242)
100 ms (ELMON rail 32-242 K)
(Power on 700ms)
Assembly
Plug-in socket to 35 mm DIN snap-on rail
Housing
11 pol. DIN plug-in socket housing
with plug-in socket for 35 mm assembly rail
Dimensions
(HxWxD)
Housing
82 x 38 x 84 mm
Housing incl. plug-in socket
82 x 38 x 110 mm
Protection class
IP20
Weight
225 g
Temperature range
-25°C to +55°C
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
2
Certifications
(In accordance with INDUS rail 71-242)
EN ISO 13849-1:2008
Categorie 3 PL e
MTTFd 170 years, DC 91%
Electronics
MTTFd 1616 years, DC 99 %
Electromechanics
B10d 1000000 / MTTFd 190 years (Nop 52560)
All voltages connected to the switching unit must be safely isolated!
84
82
38
26