6 MAN-PH-E-16
© by ASM GmbH
www.asm-sensor.com / USA: www.asmsensors.com
POSIHALL
®
Description
Installation
WARNING
The purpose of position sensors is to transform position of a linear and
guided movement into an electrical signal. Specifications of measuring
range, environment, handling and connections as specified in the catalog,
must be followed.
The catalog is part of this instruction manual. If the catalog is not available
it may be requested by stating the respective model number.
Description
Adjacent magnetic fields or ferromagnetic materials can influence the
measurement results of the PH sensors of the POSIHALL
®
product family.
Therefore the angle sensors should be mounted solely with nonmagnetic /
non magnetisable screws and washers.
The POSIHALL
®
multiturn angle sensors PH36, PH58 and PH68, PH68R
are equipped with an integrated magnetic shield which minimizes the
sensitivity against external magnetic fields
The POSIHALL
®
multiturn angle sensors can be mounted with clamping
flange or synchro flange depending on model, and therefore offer universal
mounting possibilities.
PH36
Synchro flange for the installation with mounting
clamps or mounting brackets and M3 thread at the
front
PH58
Clamping flange and M3 / M4 thread at the front
Synchro flange and M4 thread at the front
PH68/PH68R
Synchro flange and M4 thread at the front