Example: Set Transmit Cycle to 10ms, Index 31, Node-ID 247d (F7h)
PGN
HIGH
PGN
LOW
8 Byte data frame
→
0EFh
F7h
1Fh
01h
00
00
0Ah
00
00
00
←
0EFh
cc
1Fh
01h
00
00
0Ah
00
00
00
Example: Read Transmit Cycle value, Index 31
→
0EFh
F7h
1Fh
00
00
00
00
00
00
00
←
0EFh
cc
1Fh
00
00
00
0Ah
00
00
00
Example: Store Parameters permanently, Index 28
→
0EFh
F7h
1Ch
01h
00
00
65h
76h
61h
73h
←
0EFh
cc
1Ch
01h
00
00
65h
76h
61h
73h
Reload factory defaults, Index 29
→
0EFh
F7h
1Dh
01h
00
00
64h
61h
6Fh
6Ch
←
0EFh
cc
1Dh
01h
00
00
64h
61h
6Fh
6Ch
Example: Broadcast (PGNLow = 0FFh - Reload factory defaults of all sensors, Index 29
→
0EFh
0FFh
1Dh
01h
00
00
64h
61h
6Fh
6Ch
←
0EFh
cc
1Dh
01h
00
00
64h
61h
6Fh
6Ch
© by ASM GmbH
MAN-PH-E-16 33
www.asm-sensor.com / USA: www.asmsensors.com
Configuration examples
POSIHALL
®
Digital output CAN SAE J1939