4.7 Option Friction Wheel with encoder
‒ for measurements of continuous movements
Stop-time measuring system with internal memory
NMG2-...-MEM
in operation mode Multiple Measurement.
In this mode you can select the unidirectional measurement. This has an effect on the sequence of the
Multiple Measurement but has no effect on the Single Shot mode.
Mode of operation [uni-dir]
After measurement, the new zero position will be set at the standstill position. Now move in the measuring
direction to the start position and start the next measurements.
Mode of operation [Auto-rES]
After measurement, the new zero position will be set by pushing the
ZERO
[5] button. Now move in the
measuring direction to the start position and start the next measurements.
Applications
For measurements on machines with continuous movements (conveyor belts, rotating tables) you can
perform multiple measurements in series.
The stop-time of presses in dependency of the position between upper and lower dead center can be
measured in one single measurement.
To select the mode, use the setting of the parameters (see page 16):
1. Set [Fcod] with the jog wheel [9]
2. Press ZERO [5]
3. Select Unidirectional with [Uni-dir] or [Auto-rES] (back to standard mode with [Bi-dir]).