NMG2
®
Stop-Time Measuring System
16
Version 3.0.0
www.asm-sensor.com
Pos : 32 /Bedienungs anl eitungen/NM G2/Gr undeinst ellungen @ 7\ mod_1546953012858_78. doc x @ 61435 @ 2 @ 1
4.1 NMG2 basic settings
There are two ways of opening the menu for basic settings:
1. NMG2 switched off: set the button [1] in the
ADJUST
position, keep the
ZERO
button [5] pressed
‒ the
NMG2 will be switched on.
2. NMG2 switched on: set the button [1] in the
ADJUST
position, keep the
ZERO
button [5] pressed and
set the button [1] in the position
TEST
RUN
, then release the
ZERO
button [5].
Both displays show the message FUNC/END. Turn the jog wheel [9] clockwise until the display shows
FUNC. Select the needed function and press the
ZERO
[5] button. The set function will be saved; then leave
the display FUNC;END.
Basic setting of the formula parameters
FUNC;END
⇒
gr
Turn the jog wheel [9] clockwise until [gr] will appear. Press the
ZERO
[5] button to achieve the setting mode
for the hand speed, which can be adjusted now with the jog wheel. Then press the
ZERO
[5] button. Now
FUNC;END appears again.
FUNC;END
⇒
t2
Turn the jog wheel [9] clockwise until [t2] will appear. Press the
ZERO
[5] button to achieve the setting mode
for the addition to the stop time, which can be adjusted now with the jog wheel. Then press the
ZERO
[5]
button. Now FUNC;END appears again.
FUNC;END
F1
Turn the jog wheel [9] clockwise until [F1] will appear. Press the
ZERO
[5] button to achieve the setting mode
for the proportional addition factor for stop time, which can be adjusted now with the jog wheel. Then press
the
ZERO
[5] button. Now FUNC;END appears again.
FUNC;END
F2
Turn the jog wheel [9] clockwise until [F2] will appear. Press the
ZERO
[5] button to achieve the setting mode
for the addition to the safety distance, which can be adjusted now with the jog wheel. Then press the
ZERO
[5] button. Now FUNC;END appears again.
Number of measurements in automatic mode
FUNC;END
n
Push briefly the
ZERO
button [5] to achieve the setting mode for the number of measurements in automatic
mode, which can be adjusted now with the jog wheel [9]. For n=0 the automatic measurement mode will be
terminated by pressing
ADJUST
. According to ISO 13855 the preset is n = 10. Then press the
ZERO
button
[5]. Now FUNC;END appears again.
Selection of the measurement type
FUNC;END
Fcod
Push briefly the
ZERO
button [5] to achieve the setting mode for the selection of the measurement type,
which can be adjusted now with the jog wheel [9]:
•
Bi-dir: bidirectional standard measurement mode for measurements on presses etc.
•
Uni-dir: unidirectional measurement mode for continuous movements (e.g. conveyors, rotary tables)
•
AUto rES: like Uni-dir, but the
ZERO
button [5] must be pressed for a new measurement NULL [5]
•
ES24 for measurements on systems with emergency stop or 2-hand control using the switch
NMG2-KABEL-ES24V
Then press the
ZERO
button [5]. Now FUNC;END appears again.