18
309508
Pressure Control Repair
Motor Control Board
Removal
Refer to Fig. 6.
1.
Relieve pressure
;
page 9.
2.
Remove four screws (18) and cover (39).
3.
Disconnect at motor control board (35):
Four motor leads: two yellow, black (+) and
red (–).
Filter board motor leads, brown and blue.
Lead (D) from potentiometer.
Lead (E) from transducer.
4.
Remove five screws (36), circuit board (35) and
filter board (40).
Installation
1.
Clean pad on rear of motor control board. Apply
small amount of thermal compound to pad.
2.
Fig. 5. Install motor control board (35) with four
screws (36). Install filter board (40) and secure
with fifth screw (36).
3.
Connect to motor control board (35):
Lead (E) to transducer.
Lead (D) to potentiometer.
Four motor leads: two yellow, black (+) and
red (–).
Filter board leads, brown and blue.
4.
Install cover (39) with four screws (18).
Motor Control Board Diagnostics
Note:
Keep a new transducer on hand to use for test.
CAUTION
Do not allow sprayer to develop fluid pressure with-
out transducer installed. Leave drain valve open if
test transducer is used.
1.
Remove four screws (18) and cover (39).
2.
Turn ON/OFF switch ON.
3.
Observe LED operation and reference following
table:
4.
Relieve pressure and unplug sprayer before ser-
vicing control board
;
page 9.
LED
BLINKS
SPRAYER OPERATION
INDICATES
WHAT TO DO
Once
Sprayer runs
Normal operation
Do nothing
Two times
repeatedly
Sprayer shuts down and LED continues
to blink two times repeatedly
Run away pressure. Pres-
sure greater than 4500 psi
(310 bar, 31 MPa).
Replace motor control board.
See preceding Motor control
board removal procedure.
Three times
repeatedly
Sprayer shuts down and LED continues
to blink three times repeatedly
Pressure transducer is
faulty or missing
Check transducer connection.
Open drain valve. Substitute
new transducer for transducer
in sprayer. If sprayer runs,
replace transducer.
Four times
repeatedly
Sprayer shuts down and LED continues
to blink four times repeatedly
Line voltage is too high
Check for voltage supply
problems
Five times
repeatedly
Sprayer shuts down and LED continues
to blink five times repeatedly
Too much current
Check for locked rotor,
shorted wiring or motor. Re-
pair or replace failed parts.