RRM02 - Product Manual
Issue: 02 complete, approved
Page 50 of 68
6.2.2.4.1 Obtaining the Router Output Number
Check the system design documentation to find the Router audio output(s) number connected to the audio
zone.
6.2.2.4.2 Obtaining the Intermediate Router Input Number
Check the system design documentation to find the intermediate Router audio input number being used to
set-up the chime.
6.2.2.4.3 Obtaining
the
BMB01 Digital Input Number
Check the system design documentation to find the BMB01 digital input number being used to route the
audio to single audio zone.
6.2.2.4.4 Obtaining the BMB01 Digital Output Number
Check the system design documentation to find the BMB01 digital output number being used for busy
indication.
6.2.2.4.5 Configuring
BMB01
Digital Input for Routing
VAR4/12/20 Menu:
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Remote
Æ
<Remote I/O Unit=
n
>
Æ
Digital In
Æ
<Contact #
ii
>
Æ
Routing
DAU/ACU/VAR8/VAR8-ACU Menu:
Configuration
Æ
System
Æ
Router
Æ
Ctrl
Æ
Remote
Æ
<Unit Address #
n
>
Æ
Digital In
Æ
<
Æ
<Digital #
ii
>
Æ
Routing
Where
n
is the BMB01 unit address, and
ii
is the BMB01 digital input number found in Section “
6.2.2.4.4
Obtaining the BMB01 Digital Input Number
” (page
50
).
Once a digital input is configured for ‘Routing’, it is necessary to define the route(s) that it controls, and to set
the routing control parameters as described in the following steps.
1.
Configure the route(s) by associating the intermediate microphone input to the audio zone output(s)
found in Section “
6.2.2.4.1 Obtaining the Router Output Number
” (page
50
).
VAR4/12/20 Menu:
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Remote
Æ
<Remote I/O Unit=
n
>
Æ
Digital In
Æ
<Contact #
ii
>
Æ
Routing
Æ
Zoning
DAU/ACU/VAR8/VAR8-ACU Menu:
Configuration
Æ
System
Æ
Router
Æ
Ctrl
Æ
Remote
Æ
<Unit Address #
n
>
Æ
Digital In
Æ
<
Æ
<Digital #
ii
>
Æ
Routing
Æ
Zoning
2.
Configure the route(s) for non-latching operation, i.e., the activation of the contact initiates the route.
When the contact is released, the route is cleared.
VAR4/12/20 Menu:
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Remote
Æ
<Remote I/O Unit=
n
>
Æ
Digital In
Æ
<Contact #
ii
>
Æ
Routing
Æ
Control
Æ
Latching
Æ
Not-Latched
DAU/ACU/VAR8/VAR8-ACU Menu:
Configuration
Æ
System
Æ
Router
Æ
Ctrl
Æ
Remote
Æ
<Unit Address #
n
>
Æ
Digital In
Æ
<
Æ
<Digital #
ii
>
Æ
Routing
Æ
Control
Æ
Latching
Æ
Not-Latched