11.
Ensure that the DIN rail power supply disconnect lever is toggled on (see
Figure 13
).
Figure 13
Power
Supply
Terminal
BACK BOX
FIELD CABLING
+24 V INPUT – TERMINAL 4
DISCONNECT LEVER
(TOGGLED ON)
12.
Fix the RRM02 lid back in position, screwing it tight to provide an IP65 seal, but not excessively tight
so that any of the fixing threads are stressed, as this may cause them to weaken and shear.
L
This can be done after commissioning the unit, if desired. Leaving the lid off at this stage
enables the RF signal strength LEDs on the lower face of the Radio Microphone
Receiver to be seen during unit commissioning (see
Figure 14
).
Figure 14
Radio Microphone Receiver RF Level Indicators
RADIO MICROPHONE
RECEIVER
-74 dBm
-79 dBm
-86 dBm
-93 dBm
13.
Power the unit on from the central equipment rack, or wall mount Intellevac DAU or ACU.
14.
Commission the microphone as described in Section “
6 Commissioning
” (page
36
).