background image

OUT OF NEUTRAL

FUSION

START SCREEN

Standard

Main User Menu

BLUETOOTH

NEXT FUNCTION

NEXT PROFILE

POWER OFF

Attendant 

Control

Attendant 

Control

Attendant 

Control

R-Net 

Main User Menu

BLUETOOTH

TOGGLE F/R

USER MENU

SEATING

POWER OFF

Attendant 

Control

Attendant 

Control

Attendant 

Control

SLEEP

FUSION

PROGRAMMING

ACTIVATE PROGRAMMING 

SCREEN: 

Simultaneously Press Down

 on Both Buttons on the Display

SETTINGS RESET

MORE

PROGRAMMING

DIAGNOSTICS

RESET SETTINGS

PROP 

CALIBRATION MAX

PROP 

CALIBRATION MIN

SET PAD TYPE

PAD SETTINGS

SET PAD 

DIRECTION

SET MINIMUM

SPEED

R-NET ENABLED

IF R-NET

 IS

 ENABLED

ATTENDANT 

SETTINGS

SET VEER ADJUST

PERFORMANCE

SETTINGS

USER SETTINGS

FEATURE LIST

IF R-NET IS 

NOT

 ENABLED

R-NET ENABLED

FAULT SCREEN

FAULT SCREEN

FAULT SCREEN

F U S I O N   P R O G R A M M I N G   D I A G R A M

F U S I O N   P R O G R A M M I N G   D I A G R A M

For more assistance, visit the

 165 

FUSION Display, Programmer and 
Attendant Control Interactive Guide 

on the ASL website.

ATOM

 Technology

Powered by

 

Содержание FUSION 165

Страница 1: ...ammer and Attendant Control Adaptive Switch Laboratories Inc www asl inc com SCAN FOR PROGRAMMING INFORMATION CONNECTOR 6 FT WIRE LENGTH 3 50 2 13 0 84 The 165 FUSION DIsplay Programmer and Attendant Control is to be used with the ASL 110 FUSION Proportional and Digital Head Array ...

Страница 2: ...ISPLAY PROGRAMMER AND ATTENDANT CONTROL The ASL 165 FUSION Display Programmer and Attendant Control has multiple features It can be used to personalize the FUSION to the specific patients needs It can also be used as a display so the patient will know what they are controlling such as Bluetooth Next Function Next Profile and On Off of the Head Array In addition the 165 FUSION can be used as an Att...

Страница 3: ...et system a momentary press of the user switch when sleep is on the top lineoftheFUSIONDisplaywillsend a three second switch activation to put the power chair into sleep mode A second activation will wake up the power chair Long hold must be set to three seconds in R Net programming for this feature to work MAIN USER SLEEP When the user taps the Attendant Control icon the programmer will display t...

Страница 4: ... someone is not using Bluetooth through the FUSION or does not need access to the R Net User Menu you can slide them to Off and they will not appear on the main screen FEATURE SETTINGS IN R NET ATTENDANT SETTING The Attendant Settings screen is displayed when the ATTENDANT SETTING button is pressed from the Pad Performance screen When the Proportional line is green the Attendant Control will work ...

Страница 5: ...e of the screen Moving your finger to the very edge of the outer circle will move the chair faster Moving your finger around the circle moves the chair in the corresponding direction When the FUSION Head Array image is on the screen the Attendant function works as an assist Meaning it works in conjunction with the FUSION if a person using the FUSION needs a little help while they are driving You c...

Страница 6: ...ons on the Display SETTINGS RESET MORE PROGRAMMING DIAGNOSTICS RESET SETTINGS PROP CALIBRATION MAX PROP CALIBRATION MIN SET PADTYPE PAD SETTINGS SET PAD DIRECTION SET MINIMUM SPEED R NET ENABLED IF R NET IS ENABLED ATTENDANT SETTINGS SETVEER ADJUST PERFORMANCE SETTINGS USER SETTINGS FEATURE LIST IF R NET IS NOT ENABLED R NET ENABLED FAULT SCREEN FAULT SCREEN FAULT SCREEN FUSION PROGR AMMING DIAGR ...

Страница 7: ...way in order to prevent damage by crushing cutting or snagging Incorrect installation configuration or programming could result in unsafe set up of the wheelchair for the user ASL accepts no liability for losses of any kind which result for such conditions Installation of the ASL 165 FUSION Display Programmer and Attendant Control and the programming of the wheelchair electronics should only be co...