background image

PROGRAMMING THE  DISPLAY

Activating the 165 Display Programming Screen: 

Simultaneously press down on both top 
and bottom circular buttons on the right 
side of the display. This will activate the 
screen to begin programming. 

R-NET FEATURES IN FUSION

When the Toggle F/R is 
highlighted, a momentary press 
of the switch in the user port will 
toggle the Drive Control from 
forward to reverse. 

MAIN USER - 

TOGGLE F/R

A momentary press of the switch 
while in R-Net Seating will turn 
the back pad of the FUSION Off. 
This will automatically change the 
left and right pad to work in Digital 
for easy access and navigation.   A 
momentary activation of the 
switch will turn the back pad on 
and take you back to the User 
Menu where a momentary switch 
activation will exit the menu, so 
you can go back to driving. 

MAIN USER - 

SEATING

When User Menu is highlighted 
a momentary press will put the 
R-Net Omni into the User Menu 
which will allow someone to 
access the list of modes such as, 
Seating, Speed Adjust, and Lights.  
The backpad of the FUSION will 
scroll you through the list of 
modes.  To select a desired mode 
like Seating, you activate the right 
pad which gives you access to the 
Seating Options. A long hold will 
take you to the Seating Mode.

MAIN USER - 

USER MENU

When the R-Net Feature is 
enabled, it displays the R-Net 
Main User Screen. This indicates 
that the system will be set up to 
be used with R-Net electronics.  A 
long press will advance to the next 
feature. 

R-NET ENABLED

The R-Net Main User Screen shows 
all the Functions available on the 
FUSION with the R-Net Feature 
Enabled and Power On/Off Feature 
Active.  When the patient holds the 
switch to the adjusted time, the 
system will move to the next line 
item in the FUSION display.  When 
the same switch is then activated 
in a momentary activation, it will 
activate that selection. 

R-NET MAIN USER

When the Power On/Off is 
highlighted a momentary switch 
activation will turn the FUSION 
off and on.  When the FUSION is 
Off, the screen will change color 
to indicate the Head Array is off 
and will not react to any pad 
activation. 

POWER OFF

R-NET MAIN USER 

 BLUETOOTH

In Bluetooth Mode the FUSION 
will connect to (3) three ASL 
Accessories, one at a time, shown 
below:  

557-3 Bluetooth 

Switch Interface

558 Mouse Emulator

545 Tecla E

Once in the Bluetooth Mode, the 
FUSION will automatically connect 
to the selected powered receiver 
and the FUSION Head Array will be 
the activation for that accessory.

When sleep setting is turned 
on within the R-Net system, a 
momentary press of the user 
switch when sleep is on the top 
line of the FUSION Display will send 
a three second switch activation 
to put the power chair into sleep 
mode.  A second activation will 
wake up the power chair.   Long 
hold must be set to three seconds 
in R-Net programming for this 
feature to work.  

MAIN USER - 

SLEEP

When the user taps the Attendant 
Control icon, the programmer will 
display the Attendant Control 
screen.  When the display is 
showing the full screen attendant 
option, the Attendant Control is 
active.

MAIN USER - 

ATTENDANT CONTROL

When the Attendant Control is turned on and pressed, the following screen is 
displayed. 

Left:

  Attendant and Head Array are active.

Center: 

 Attendant is active, Head Array is inactive.

Right:

  FUSION is powered off.  Attendant is active and Head Array is off.

MAIN PROGRAMMING 

   

FUSION 165 DISPL AY, PROGRAMMER AND AT TENDANT CONTROL 

Tapping “Prop” on the pad will change it 
from Proportional to Digital by each pad 
or direction. 

In this example, the Left and Center Pad 
are set to Proportional and the Right Pad 
is set to Digital.

PAD TYPE

When the Proportional Programmed Pad is 
held for 2 seconds a calibration screen will 
appear. You will be guided to set up the 
Minimum and Maximum force required to 
gain proportionality. 

When you push on the pad the green color 
is a real time guide for the pressure that 
a person is pushing on the pad. This can 
be set by each direction.  The

 Minimum

 

(in yellow) sets the force required to 
initiate the proportional movement.  The 

Maximum 

(in red) sets the force to reach 

100% of the programmed speed.  

CALIBRATION MIN

CALIBRATION MAX

 

Set Minimum Speed

: This setting will 

allow each pad on the FUSION to change 
the percentage of Digital to start the 
movement of the chair.  

The factory setting in each pad is set to 
20%. This will start the initial movement of 
the chair for the first 20% of the speed to be 
Digital. Pressing into the pads will make the 
chair move proportionally. 

The selections are 

15, 20, 

25, 30, 35, 40 

and 

OFF.

MINIMUM SPEED

PAD DIRECTION

This allows the driving direction to change 
by pad.  Touching the direction will scroll 
clockwise starting with the factory set 
direction.

The back pad will move from 

Forward, 

Right, Off, Left

 and then back to 

Forward

.  This is helpful for a patient 

that needs the back pad for a rest. 

You can turn off the back pad, change the 
right switch to be forward, and move the 
right direction to another location such 
as,  a hand or knee.

The Initial Programming Screen is 
activated by pressing the top and 
bottom buttons simultaneously for 2 
seconds.  When Pad Settings is selected 
a new screen will appear. 

PROGRAMMING

Set “Pad Type” directs you to the 
Proportional Digital Selection. 

PAD SETTINGS

Содержание FUSION 165

Страница 1: ...ammer and Attendant Control Adaptive Switch Laboratories Inc www asl inc com SCAN FOR PROGRAMMING INFORMATION CONNECTOR 6 FT WIRE LENGTH 3 50 2 13 0 84 The 165 FUSION DIsplay Programmer and Attendant Control is to be used with the ASL 110 FUSION Proportional and Digital Head Array ...

Страница 2: ...ISPLAY PROGRAMMER AND ATTENDANT CONTROL The ASL 165 FUSION Display Programmer and Attendant Control has multiple features It can be used to personalize the FUSION to the specific patients needs It can also be used as a display so the patient will know what they are controlling such as Bluetooth Next Function Next Profile and On Off of the Head Array In addition the 165 FUSION can be used as an Att...

Страница 3: ...et system a momentary press of the user switch when sleep is on the top lineoftheFUSIONDisplaywillsend a three second switch activation to put the power chair into sleep mode A second activation will wake up the power chair Long hold must be set to three seconds in R Net programming for this feature to work MAIN USER SLEEP When the user taps the Attendant Control icon the programmer will display t...

Страница 4: ... someone is not using Bluetooth through the FUSION or does not need access to the R Net User Menu you can slide them to Off and they will not appear on the main screen FEATURE SETTINGS IN R NET ATTENDANT SETTING The Attendant Settings screen is displayed when the ATTENDANT SETTING button is pressed from the Pad Performance screen When the Proportional line is green the Attendant Control will work ...

Страница 5: ...e of the screen Moving your finger to the very edge of the outer circle will move the chair faster Moving your finger around the circle moves the chair in the corresponding direction When the FUSION Head Array image is on the screen the Attendant function works as an assist Meaning it works in conjunction with the FUSION if a person using the FUSION needs a little help while they are driving You c...

Страница 6: ...ons on the Display SETTINGS RESET MORE PROGRAMMING DIAGNOSTICS RESET SETTINGS PROP CALIBRATION MAX PROP CALIBRATION MIN SET PADTYPE PAD SETTINGS SET PAD DIRECTION SET MINIMUM SPEED R NET ENABLED IF R NET IS ENABLED ATTENDANT SETTINGS SETVEER ADJUST PERFORMANCE SETTINGS USER SETTINGS FEATURE LIST IF R NET IS NOT ENABLED R NET ENABLED FAULT SCREEN FAULT SCREEN FAULT SCREEN FUSION PROGR AMMING DIAGR ...

Страница 7: ...way in order to prevent damage by crushing cutting or snagging Incorrect installation configuration or programming could result in unsafe set up of the wheelchair for the user ASL accepts no liability for losses of any kind which result for such conditions Installation of the ASL 165 FUSION Display Programmer and Attendant Control and the programming of the wheelchair electronics should only be co...

Отзывы: