background image

SETTINGS

MAIN PROGRAMMING

 

SETTINGS 

USER SETTINGS

Timeout:  

The length of time that the User Switch has to be held to move to the next 

setting.  The adjustment range is in seconds:  

1 sec, 1.5, 2, 2.5, 3, 4, 5, and OFF. 

R-Net Enable:

   Changes the User Screen to R-Net features for easier access.

Mode (Reverse):

 The Slide switch will change how the mode switch responds to 

activation.   The choices are Mode and Reverse.

The Settings Screen will allow the 
Auditory beeps to be turned on and off.  

Power Up Idle: 

 When this setting is on it will allow the FUSION to stay off when 

the chair is turned on. An activation of the User Switch will turn the system on 
when a patient is ready to move. 

The Veer Adjust will help a chair drive in a straight line by 
adjusting the signal from the FUSION Input to the Controller.   

The range is from

 -20  to +20.

  Each chair will have a 

slightly different setting. The Factory Setting is set at 

-2

VEER ADJUSTMENT

This will allow the FUSION Features in R-Net 
that a person is Not Using to be turned Off.  

If someone is not using Bluetooth through 
the FUSION, or does not need access to the 
R-Net User Menu, you can slide them to 
Off and they will not appear on the main 
screen.

FEATURE  SETTINGS IN R-NET

ATTENDANT SETTING

The Attendant Settings screen is displayed 
when the “ATTENDANT SETTING” button is 
pressed from the Pad Performance screen.

When the Proportional line is green the 
Attendant Control will work proportionally.  
When it is not green, it works as a Digital 
Control. 

FUSION 165 DISPL AY, PROGRAMMER AND AT TENDANT CONTROL 

The Pad Performance screen is displayed 
when the “PERFORMANCE” button is 
pressed from the Pad Settings screen.

PAD PERFORMANCE

FUSION 165 DISPL AY, PROGRAMMER AND AT TENDANT CONTROL 

SETTINGS

This screen is shown when the USER 
SETTINGS button is pressed from the 
Main Programming screen.

This screen is shown when the USER 
SETTINGS button is pressed from the 
Main Programming screen.

MAIN PROGRAMMING

 

SETTINGS CONTINUED

FEATURE SETTINGS

This will allow the FUSION 
Features that a person is 
Not Using to be turned OFF. 

If someone is not using Bluetooth 
through the FUSION, or is not 
changing Profiles, you can slide 
them to OFF and they will not 
appear on the Main Menu. 

Содержание FUSION 165

Страница 1: ...ammer and Attendant Control Adaptive Switch Laboratories Inc www asl inc com SCAN FOR PROGRAMMING INFORMATION CONNECTOR 6 FT WIRE LENGTH 3 50 2 13 0 84 The 165 FUSION DIsplay Programmer and Attendant Control is to be used with the ASL 110 FUSION Proportional and Digital Head Array ...

Страница 2: ...ISPLAY PROGRAMMER AND ATTENDANT CONTROL The ASL 165 FUSION Display Programmer and Attendant Control has multiple features It can be used to personalize the FUSION to the specific patients needs It can also be used as a display so the patient will know what they are controlling such as Bluetooth Next Function Next Profile and On Off of the Head Array In addition the 165 FUSION can be used as an Att...

Страница 3: ...et system a momentary press of the user switch when sleep is on the top lineoftheFUSIONDisplaywillsend a three second switch activation to put the power chair into sleep mode A second activation will wake up the power chair Long hold must be set to three seconds in R Net programming for this feature to work MAIN USER SLEEP When the user taps the Attendant Control icon the programmer will display t...

Страница 4: ... someone is not using Bluetooth through the FUSION or does not need access to the R Net User Menu you can slide them to Off and they will not appear on the main screen FEATURE SETTINGS IN R NET ATTENDANT SETTING The Attendant Settings screen is displayed when the ATTENDANT SETTING button is pressed from the Pad Performance screen When the Proportional line is green the Attendant Control will work ...

Страница 5: ...e of the screen Moving your finger to the very edge of the outer circle will move the chair faster Moving your finger around the circle moves the chair in the corresponding direction When the FUSION Head Array image is on the screen the Attendant function works as an assist Meaning it works in conjunction with the FUSION if a person using the FUSION needs a little help while they are driving You c...

Страница 6: ...ons on the Display SETTINGS RESET MORE PROGRAMMING DIAGNOSTICS RESET SETTINGS PROP CALIBRATION MAX PROP CALIBRATION MIN SET PADTYPE PAD SETTINGS SET PAD DIRECTION SET MINIMUM SPEED R NET ENABLED IF R NET IS ENABLED ATTENDANT SETTINGS SETVEER ADJUST PERFORMANCE SETTINGS USER SETTINGS FEATURE LIST IF R NET IS NOT ENABLED R NET ENABLED FAULT SCREEN FAULT SCREEN FAULT SCREEN FUSION PROGR AMMING DIAGR ...

Страница 7: ...way in order to prevent damage by crushing cutting or snagging Incorrect installation configuration or programming could result in unsafe set up of the wheelchair for the user ASL accepts no liability for losses of any kind which result for such conditions Installation of the ASL 165 FUSION Display Programmer and Attendant Control and the programming of the wheelchair electronics should only be co...

Отзывы: