4.Troubleshooting guide:
5.
Warranty :
We warrant this product against defects in materials and workmanship during warranty period and
will repair or replace any defective power inverter when directly returned (postage paid) to us.
This warranty will be considered void if the unit has suffered any obvious damage by natural and
man-made factors, or alteration either internal or external and does not cover damage arising from
improper use such as plugging the unit into an unsuitable power sources attempts to operate
products with excessive power consumption requirement, or use in unsuitable environments.
This is the only warranty that the company makes.
No other warranties express or imply including warranties of merchantability and fitness for a
particular purpose.
Repair and replacement are your sole remedies and the company shall not be liable for damages,
whether direct, incidental, special or consequential, even though caused by negligence or other
fault.
WARNING!
Do not open or disassemble the inverter. Attempting to service
the unit yourself may result in a risk of electrical shock or fire.
Problem and Symptom
Possible Cause
Solution
Low output voltage
(220V: 190-210VAC)
Using average reading
voltmeter
Use true RMS reading meter
and cable. (Ref. point 2-4-7).
Load display OLP flash
Over load
Reduce load
No output voltage
Fault input voltage
Input Undervoltage
Input Overvoltage
Recharge battery,
check connections and cable.
( Ref. point 2-5 & point 2-6)
No output voltage
Over temp indicator
Load less than 500W
Thermal shutdown
Improve ventilation.
Make sure ventilation openings
in inverter are not obstructed.
Reduce ambient temperature.
No output voltage
Over load indicator
Short circuit or wiring error
Very high power load
Check AC wiring for short
circuit or improper polarity. (hot
and neutral reversed)
Remove load.