4.Troubleshooting guide:   

   

 
 
 
 

 

 

5. 

Warranty :   

We warrant this product against defects in materials and workmanship during warranty period and 

will repair or replace any defective power inverter when directly returned (postage paid) to us. 

This warranty will be considered void if the unit has suffered any obvious damage by natural and 

man-made factors, or alteration either internal or external and does not cover damage arising from 

improper  use  such  as  plugging  the  unit  into  an  unsuitable  power  sources  attempts  to  operate 

products with excessive power consumption requirement, or use in unsuitable environments. 

This is the only warranty that the company makes. 

No  other  warranties  express  or  imply  including  warranties  of  merchantability  and  fitness  for  a 

particular purpose. 

Repair and replacement are your sole remedies and the company shall not be liable for damages, 

whether  direct,  incidental,  special  or  consequential,  even  though  caused  by  negligence  or  other 

fault.   

 

 

 

WARNING! 

Do not open or disassemble the inverter. Attempting to service 
the unit yourself may result in a risk of electrical shock or fire. 

Problem and Symptom 

Possible Cause 

Solution 

Low output voltage 
(220V: 190-210VAC) 

Using average reading 
voltmeter 

Use true RMS reading meter 
and cable. (Ref. point 2-4-7). 

Load display OLP flash 

Over load 

Reduce load 

No output voltage 
Fault input voltage 

Input Undervoltage       
Input Overvoltage 

Recharge battery, 
check connections and cable. 
( Ref. point 2-5 & point 2-6) 

No output voltage 
Over temp indicator 
Load less than 500W 

Thermal shutdown 

Improve ventilation. 
Make sure ventilation openings 
in inverter are not obstructed. 
Reduce ambient temperature. 

No output voltage 
Over load indicator 

Short circuit or wiring error 
Very high power load 

Check AC wiring for short 
circuit or improper polarity. (hot 
and neutral reversed) 
Remove load. 

Содержание 1U1KVA Series

Страница 1: ...R lingsvei 261 2008 Fjerdingby Tlf 63 83 33 90 Mobil 90032394 www extron no e post post extron no 1U 19 23 Open Rack Inverter 1U1KVA 1U2KVA Series Pure Sine Wave Inverter YK PSW241KVAE YK PSW242KVAE...

Страница 2: ...3 Installation 8 2 4 Quick hook up and testing 9 2 5 AC safety grounding 10 2 6 Making DC wiring connections 11 2 7 Inverter operation 12 2 8 Cooling fan working code 14 3 Maintenance 14 4 Troubleshoo...

Страница 3: ...ols circular saws drills grinders sanders buffers weed and hedge trimmers air compressors 1 1 2 Office equipment computers printers monitors facsimile machines scanner 1 1 3 Household items vacuum cle...

Страница 4: ...ervoltage Over Temperature Digital Display OVP UVP OTP OLP VAC AMP WATT VDC TEMP Hz Safety EN60950 1 EMC EN 55022 2010 AC 2011 Class B EN 55024 2010 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2013...

Страница 5: ...e Over Temperature Digital Display OVP UVP OTP OLP VAC AMP WATT VDC TEMP Hz Safety EN60950 1 EMC EN 55022 2010 AC 2011 Class B EN 55024 2010 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2013 IEC 610...

Страница 6: ...5 1 3Mechanical Drawings...

Страница 7: ...ons in this manual before installing and using this model 2 1 Front Panel Operation 2 1 1 Front view 2 1 2 ON OFF switch Please leave in the OFF position during installation 2 1 3 Function Key When se...

Страница 8: ...nect to 12V 24V 48V battery or other 12V 24V 48V power Source is positive is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently WARNING Do not connect the...

Страница 9: ...ay result in an electrical safety hazard WARNING Shock Hazard Before proceeding further carefully check the inverter is NOT connected to any batteries and that all wiring is disconnected from any elec...

Страница 10: ...battery These gases are very corrosive and prolonged exposure will damage the Inverter 2 4 Quick hooking up and testing 2 4 1 Unpack and inspect the power inverter check to see that the power switch...

Страница 11: ...rnal alarm Then the AC voltage shows on the display It means the device has done the operation 2 4 6 Set the power switch to the OFF position the device shut down completely 2 4 7 Please use a power m...

Страница 12: ...between the DC source and the point of connection of the earthing electrode conductor 2 6 Marking DC Wiring Connections Follow this procedure to connect the battery cables to the DC input terminals o...

Страница 13: ...ents for all the loads at once 2 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off The Inverter operates from an input voltage ranging from 10 0...

Страница 14: ...7 8 Over voltage protection indicator OVP The over voltage indicator indicates that the power inverter has shut itself down because its input voltage exceeded 12 24V 48VDC version Ref point 2 7 1 2 7...

Страница 15: ...gy sources requirement Until output power is up to 300W the cooling fan will start to work in order to drop the inner temperature If the ventilation opening is obstructed the inverter will enter over...

Страница 16: ...dies and the company shall not be liable for damages whether direct incidental special or consequential even though caused by negligence or other fault WARNING Do not open or disassemble the inverter...

Страница 17: ...s any space containing gasoline powered machinery fuel tanks or joints fittings or other connection between components of the fuel system 6 2 Precautions When Working with Batteries 6 2 1 If battery a...

Страница 18: ...0 OFF ON 4800 OFF ON 220 ON OFF 9600 ON OFF 230 ON ON 19200 ON ON 240 S1 FREQ Hz 50Hz 60Hz S2 S3 BAUD RATE 2400 4800 9600 19200 S4 S5 VOLTAGE OUTPUT 200VAC 220VAC 230VAC 240VAC When you set up S1 S5 p...

Отзывы: