10
CAUTION!
Reverse polarity connection will blow a fuse in inverter and may
permanently damage
the inverter.
Damage caused by reversing polarity connection is not covered by
our warranty.
2-4-4 Connect the cable from the negative terminal of the inverter to the negative terminal of
the power source. Make a secure connection.
WARNING!
You may observe a spark when you make this connection since
current may flow to charge capacitors in the power inverter.
Do not make this connection in the presence of flammable fumes.
Explosion or fire may result.
2-4-5 Set the power switch to the ON position; you will hear the “bi-bi-bi” sound. At the same
time, the display is showed the word “ASIAN” for two times. After that, you will hear the
continuous sound from internal alarm. Then, the AC voltage shows on the display. It
means the device has done the operation.
2-4-6 Set the power switch to the OFF position; the device shut down completely.
2-4-7
Please use a power meter accurately measure the true output R.M.S. voltage of inverter.
We use a power meter such as IDRC CP-350 or ABM 2019 to measure our product.
2-5. AC Safety Grounding:
During the AC wiring installation, Ac input and output ground wires are connected to the
inverter. The AC input ground wire must connect to the incoming ground from your AC utility
source.
The AC output ground wire should go to the grounding point for your loads ( for example, a
distribution panel of bus chassis).
2-5-1 Neutral Grounding (GFCI’ s ):
2-5-1-1
230V models:
There is no connection made inside the Inverter from either the line or
neutral conductor to the safety ground.
WARNING!
Do not operate the power inverter without connecting it to
Ground.
Electrical shock hazard may result.
Содержание 1U1KVA Series
Страница 6: ...5 1 3Mechanical Drawings...