47
Operating Manual - nX, nXe, and nXp Power Amplifiers
11.6 neWR-5 Programmable Button Controller
(nXe and nXp only)
-
The neWR-5 remote control is a networked version of the WR-5, using Ethernet instead of the data port to communicate
with the amplifier. Connecting and powering the neWR-5 is done using Cat-5 Ethernet cable and an IEEE 802.3af Power over
Ethernet (PoE) switch, hub, or in-line PoE injector. If PoE is unavailable, the Ashly RPS-18 (sold separately) provides 15-
48VDC capable of at least 2 watts per neWR-5 and can be hard wired to the back of the neWR-5. PoE current draw is 38mA
@48VDC and 80mA@15VDC. A decora cover plate (not included) can be purchased at hardware stores to cover the neWR-5
electrical box and satisfy the aesthetic needs of the installation.
To avoid potential static discharge disruptions to the neWR-5
or it's data signal, connect the decora plate and neWR-5 frame directly to Earth Ground at the point of installation.
The neWR-5 appears in the Protea
ne
software device menu tree and must be assigned to the amplifier under control. The neWR-
5 has six programmable function buttons which light up green, red, or amber to display status. Further information on LED status is
found in the
neWR-5 owner's manual
. To the right of the function buttons is a clear window for a printed function label to be inserted.
The two other buttons are used to adjust function parameters such as gain or preset number, and are indicated by the LED display.
There is also a hard-wired lock-out feature on the neWR-5, where the closing of a switch wired to the lock-out Euroblock
renders all buttons inactive.
11.7 FR-8 and FR-16 Networked Fader Controller
(nXe, nXp only)
The FR-8 and FR-16 are Ethernet based remote fader control units, with the ability to assign
each fader to control one or more input or output DSP gain stages (I/O mode), or control a
DSP matrix mixer input level (Mixer Mode). Each fader's button LED can alternately be
assigned as an A/B source select for that fader. The button LED for each fader is normally
used to indicate assignable signal level/clip or mute status, but can alternately indicate A/B
source selection for that fader. The FR remotes can be wall mounted to electrical box,
panel mounted, or freestanding, and have a back panel contact closure for a control lockout
switch. See further details in the
FR-8/16 owners manual
, available on the Ashly website.
11.8 INA-1 Inline RS-232 Adapter
-The nXe or nXp amplifier data port uses a pro-
prietary serial communications protocol which can be converted to RS-232 using the Ashly
INA-1
RS-232 Adapter
. This allows the use of third party RS-232 controllers. Note that the INA-1 uses a
5mm Euroblock connector while the nX amplifier uses 3.5mm Euroblock connectors, thus the cable
connection must be made accordingly. See the wiring diagram to the right.
11.6 - neWR-5 Networked Programmable Remote Control