background image

Operating Manual - 

NE

 Multi Channel Power Amplifiers

14

DSP Specifications

Input:  . . . . . . . . . . . . . . . Active Balanced, 10 kohms

Max Input Level:  . . . . . . +21 dBu

Dynamics

Brick Wall Limiter

Threshold:  . . . . . . . . . . . -20dBu to +20dBu

Ratio:  . . . . . . . . . . . . . . . infinite

Attack: . . . . . . . . . . . . . . . 0.2ms/dB to 50 ms/dB

Release:  . . . . . . . . . . . . . 5ms/dB to 1000ms/dB

Compressor

Threshold:  . . . . . . . . . . . -20dBu to +20dBu

Ratio:  . . . . . . . . . . . . . . . 1.2:1 to infinite

Attack: . . . . . . . . . . . . . . . 0.2 to 50ms

Release:  . . . . . . . . . . . . . 5ms/dB to 1000ms/dB

Detector: . . . . . . . . . . . . . Peak/Average

Autoleveler

Target Level:  . . . . . . . . . -40dBu to +20dBu

Action:  . . . . . . . . . . . . . . gentle, normal, aggressive, user

defined

Maximum Gain:  . . . . . . . 0dB to +15dB

Ratio:  . . . . . . . . . . . . . . . 1.2:1 to 10:1

Threshold Below Target: -30dB to 0dB

Gain Increase Rate:  . . . . 5ms/dB to 1000ms/dB

Hold Time:  . . . . . . . . . . . 0-6 sec

Ducker

Ducking Type:  . . . . . . . . high/low priority, trigger,

filibuster, ducked program

Trigger Threshold:  -80dBu to +20 dBu

Ducking Release:  . . . . . . 5ms/dB to 1000ms/dB

Ducking Depth:  . . . . . . . 0dB to -30dB

Gate

Threshold:  . . . . . . . . . . . -80dBu to +20dBu

Range:  . . . . . . . . . . . . . . off, 100dB to 0dB

Attack: . . . . . . . . . . . . . . . 0.2ms/dB to 50 ms/dB

Release:  . . . . . . . . . . . . . 5ms/dB to 1000ms/dB

Gain

Gain: . . . . . . . . . . . . . . . . off, -50dB to +12dB

Gain w/VCA:  . . . . . . . . . off, -50dB to +12dB

WR-5 Remote Gain:  . . . . off, -50dB to +12dB

Equalization

31 Band Graphic

Filter Type:  . . . . . . . . . . . constant Q or proportional

Bandwidth:  . . . . . . . . . . . 0.499oct to 0.25oct

2, 4, 6, or 10 Band Parametric

Filter Types

Parametric:

Frequency:  . . . . . . . . . . . 20-20kHz

Level:  . . . . . . . . . . . . . . . -30dB to +15dB

Q Value:  . . . . . . . . . . . . . 0.016oct to 4oct

Hi/Low Shelf 6/12 dB

Frequency:  . . . . . . . . . . . 20Hz-20kHz

Level:  . . . . . . . . . . . . . . . -15dB to +15dB

All Pass

Frequency 20Hz-20kHz

Variable Q HP/LP

Frequency:  . . . . . . . . . . . 20Hz-20kHz

Q Value:  . . . . . . . . . . . . . 3.047 to 0.267

Notch/Bandpass

Frequency:  . . . . . . . . . . . 20Hz-20kHz

Q Value:  . . . . . . . . . . . . . 92.436 to 0.267

Crossover

2 Way, 3 Way, 4 Way Crossover

High Pass/Low Pass Filters

Filter Types:

Bessel:  . . . . . . . . . . . . . . 12/18/24/48 dB/oct

Butterworth:  . . . . . . . . . . 12/18/24/48 dB/oct

Linkwitz:  . . . . . . . . . . . . . 12/24/48 dB/oct

Frequency:  . . . . . . . . . . . off, 20Hz-20KHz

Delay

@ 48kHz Sampling Rate

Base Delay:  . . . . . . . . . . 0-256ms

Extra Delay:  . . . . . . . . . . 0-682 ms

@ 96kHz Sampling Rate

Base Delay:  . . . . . . . . . . 0-128ms

Extra Delay:  . . . . . . . . . . 0-341 ms

Tools

Audio Meter

Range:  . . . . . . . . . . . . . . -60dBu to +20dBu

Increments:  . . . . . . . . . . . 1dB

Peak Hold Indicator:  . . . yes

Signal Generator: . . . . . . pink noise, white noise, sine wave

Sine Wave Frequency:  . . 20Hz-12kHz

Signal Level:  . . . . . . . . . . off, -50dBu to +20dBu

Cross Point Mixer

Gain:  . . . . . . . . . . . . . . . . Off., -50 to +12dB, 0.5dB

increments with Mute

Содержание ne 4200.10

Страница 1: ...er NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 www ashly com ne 4250 ne 8250 ne 4250 25 ne 8250 25 ne 4250 70 ne 8250 70 ne 4250 10 ne 8250 10 Network Enabled Multi Channe...

Страница 2: ...6 Front Panel Features 6 Rear Panel Features 7 Installation Requirements 7 Constant Voltage Models 25V 70V and 100V and High Pass Filters 7 4 REMOTE CONTROL 8 On Off Remote Standby 8 Preset Recall 8...

Страница 3: ...OVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPlIANCE TO RAIN OR MOISTURE TO REDUCE THE...

Страница 4: ...ustomer FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accep...

Страница 5: ...to 35 presets subpresets can be stored within the amplifier and can be recalled in real time from a computer WR 5 remote control or contact closure switches up to four 2 AES EBU Input Using an option...

Страница 6: ...tput voltage is 1 2 volt below the output power supply voltage 7 Bridge This LED indicates that the channel pair is selected to BRIDGE mode from the back panel switch and that only the odd input chann...

Страница 7: ...UTION When mounting or connecting the amplifier always disconnect it from the mains Use four screws and washers when mounting the amplifier to the front rack rails Rear support is also recommended esp...

Страница 8: ...isabled from software the front panel DISABLE LED will light The power switch will remain inactive until enabled again from software even if the amp is removed from power Preset Recall The four contac...

Страница 9: ...or visit the Ashly web site at www ashly com for more WR 5 details RD 8C or RW 8C Remote Control A second microprocessor based controller the Ashly RD 8C is an eight channel wall mount level controll...

Страница 10: ...vices are networked Linking of multiple devices is managed through LINK GROUPS Each Proteane device will support up to eight Link Groups DSP function blocks may be assigned to these groups though Prot...

Страница 11: ...ials indicate the physical position of hardware controls on either the amp front panel or the remote level control if present Note that these will display the position of attenuators even when DISABLE...

Страница 12: ...elp Menu Contents and Index Contents Protea NE Products PE Multichannel Amplifiers DSP Control for details of all DSP func tions The key features include 1 Input Channel Number Right click on this to...

Страница 13: ...Hz 20kHz 1 THD 150W 4 ohms 20Hz 20kHz 1 THD 250W Bridge Mode 8 ohms 20Hz 20kHz 1 THD 500W 25 70 100 Volt models 20Hz 20kHz 1 THD per channel 250W Signal to Noise 20Hz 20KHz unweighted 98dB Power Requi...

Страница 14: ...ain Gain off 50dB to 12dB Gain w VCA off 50dB to 12dB WR 5 Remote Gain off 50dB to 12dB Equalization 31 Band Graphic Filter Type constant Q or proportional Bandwidth 0 499oct to 0 25oct 2 4 6 or 10 Ba...

Страница 15: ...l Audio Input Type 110 ohm transformer balanced XLR Sample Rates 48kHz 96kHz Max Cable Length 100 meters 7 WARRANTY INFORMATION The unit you have just purchased is protected by a limited five year war...

Страница 16: ...annel Power Amplifiers ASHLY AUDIO INC 847 Holt Road Webster NY 14580 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly com 2008 by Ashly Audio Corporation All rights reserved world...