background image

Operating Manual - 

NE

 Multi Channel Power Amplifiers

6

Physical Description

Each model in the NE Multichannel series is 2RU, and weighs 22 pounds (10kg) or less.  The model number is

indicated in the lower left corner of the front panel.

Amplifier Front Panel

1. Mounting Holes 

– For rack mounting.

2. Power Switch 

– Switches the unit on or off.  

Note:  The power switch can be disabled from 

Protea

ne

 

Software

3. Status LEDs 

– Indicate status of: Power, Standby, Protect, Power Switch Disable,  and Comm activity

4. Air Inflow Vents 

– Cool air enters here

5. Channel Controls 

– Channel control area

6. Signal LEDs 

– The lowest LED will begin to light when the output voltage reaches -18dBu below rated output.

The Clip LEDs will begin to flash when output voltage is 1/2 volt below the output power supply voltage.

7. Bridge 

– This LED indicates that the channel pair is selected to BRIDGE mode from the back panel switch, and

that only the odd input channel level control is active

8. Temp and Current LEDs 

– The Temp LED indicates that the amplifier has reached an excessively high

operating temperature.  The Current LED confirms that the amplifier output is delivered to a speaker load.

9. Channel Attenuators 

– These control the input signal level to the amp, and can be disabled from software.

10. Factory Reset 

– To reset all internal configurations (including passwords) back to their original factory set-

tings, press and hold this recessed front panel tact switch during power up until all channel LEDs are lit.  Upon reset

completion, the LEDs will turn off and the amp will be in normal operating mode.

Amplifier Rear Panel

Model shown:

  ne8250 with Cobranet and AES/EBU options

Содержание ne 4200.10

Страница 1: ...er NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 www ashly com ne 4250 ne 8250 ne 4250 25 ne 8250 25 ne 4250 70 ne 8250 70 ne 4250 10 ne 8250 10 Network Enabled Multi Channe...

Страница 2: ...6 Front Panel Features 6 Rear Panel Features 7 Installation Requirements 7 Constant Voltage Models 25V 70V and 100V and High Pass Filters 7 4 REMOTE CONTROL 8 On Off Remote Standby 8 Preset Recall 8...

Страница 3: ...OVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPlIANCE TO RAIN OR MOISTURE TO REDUCE THE...

Страница 4: ...ustomer FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accep...

Страница 5: ...to 35 presets subpresets can be stored within the amplifier and can be recalled in real time from a computer WR 5 remote control or contact closure switches up to four 2 AES EBU Input Using an option...

Страница 6: ...tput voltage is 1 2 volt below the output power supply voltage 7 Bridge This LED indicates that the channel pair is selected to BRIDGE mode from the back panel switch and that only the odd input chann...

Страница 7: ...UTION When mounting or connecting the amplifier always disconnect it from the mains Use four screws and washers when mounting the amplifier to the front rack rails Rear support is also recommended esp...

Страница 8: ...isabled from software the front panel DISABLE LED will light The power switch will remain inactive until enabled again from software even if the amp is removed from power Preset Recall The four contac...

Страница 9: ...or visit the Ashly web site at www ashly com for more WR 5 details RD 8C or RW 8C Remote Control A second microprocessor based controller the Ashly RD 8C is an eight channel wall mount level controll...

Страница 10: ...vices are networked Linking of multiple devices is managed through LINK GROUPS Each Proteane device will support up to eight Link Groups DSP function blocks may be assigned to these groups though Prot...

Страница 11: ...ials indicate the physical position of hardware controls on either the amp front panel or the remote level control if present Note that these will display the position of attenuators even when DISABLE...

Страница 12: ...elp Menu Contents and Index Contents Protea NE Products PE Multichannel Amplifiers DSP Control for details of all DSP func tions The key features include 1 Input Channel Number Right click on this to...

Страница 13: ...Hz 20kHz 1 THD 150W 4 ohms 20Hz 20kHz 1 THD 250W Bridge Mode 8 ohms 20Hz 20kHz 1 THD 500W 25 70 100 Volt models 20Hz 20kHz 1 THD per channel 250W Signal to Noise 20Hz 20KHz unweighted 98dB Power Requi...

Страница 14: ...ain Gain off 50dB to 12dB Gain w VCA off 50dB to 12dB WR 5 Remote Gain off 50dB to 12dB Equalization 31 Band Graphic Filter Type constant Q or proportional Bandwidth 0 499oct to 0 25oct 2 4 6 or 10 Ba...

Страница 15: ...l Audio Input Type 110 ohm transformer balanced XLR Sample Rates 48kHz 96kHz Max Cable Length 100 meters 7 WARRANTY INFORMATION The unit you have just purchased is protected by a limited five year war...

Страница 16: ...annel Power Amplifiers ASHLY AUDIO INC 847 Holt Road Webster NY 14580 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly com 2008 by Ashly Audio Corporation All rights reserved world...

Отзывы: