background image

7

Operating Manual - 

NE 

Multi Channel Power Amplifiers

Amplifier Rear Panel

1. Optional Cobranet Card CNM-2 

– Installation of this option allows this amplifier to be part of a Cobranet

audio network.

2. Optional AES/EBU Input or MIC Input 

- Installation of this option allows for AES/EBU 

or 

MIC inputs.

3. Ethernet Port 

- This offers ethernet control and monitoring of amplifier functions using 

Protea

ne 

 software.

4.  Input Connector 

- This is used for a three wire (G, +, -) balanced input, and uses two-piece

euroblock connectors.

5. Normal/Bridge Switch 

- This switches the channel pair to Bridge Mode

6. Euroblock Speaker Connectors 

- Used to connect the speakers

7. Remote Standby 

- These two contact closure pins are wired to a switch to remotely place the amp in standby.

8. Preset Recall 

- These four pins (and GND) can be wired to remote contact closure switches to recall up to four

amplifier presets.

9. Data 

- These four pins can be wired to remote microprocessor based controllers such as the WR-5 or RD-8C.

10. Remote Level Control 

- These pins can be wired to remote potentiometers such as the WR-1 for level control

of individual channels

11. AC Inlet 

- Used for the detachable AC cord.

WARNING:  Do not remove or lift the mains connector ground.

Installation

Before connecting to mains power, make sure that the switches and wiring are all set to the configuration needed

for your particular application. Failure to do so could result in damage to the unit or other components in your system.

CAUTION: 

When mounting or connecting the amplifier, always disconnect it from the mains. Use four screws and

washers when mounting the amplifier to the front rack rails. Rear support is also recommended, especially for mobile or

touring use. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

Requirements

NE-series multichannel amplifiers have specific physical, electrical and signal requirements for proper operation.

These requirements will vary de pending on your specific application, setup, and the settings on the amplifier. When

setting up and testing your system, please take special care to double check all connections and settings. Please refer to

the specifications section of this manual for specific input, output and other figures.

Constant Voltage Models (25V, 70V, and 100V) and High Pass Filters

The 25V, 70V, and 100V amplifiers include internal, factory installed High Pass Filter hardware. This allows for

software  selectable  filters  on  each  channel  that  prevent  low  frequency  energy  from  saturating  the  core  of  low  cost

speaker tap transformers.  Available settings are 80Hz (12dB/oct), 400Hz (6dB/oct), and OFF.  The 400Hz setting is

commonly used in paging systems with horn speakers.  

Note that with the HPF hardware  installed, that amplifier can

not have any of the optional AES/EBU input, MIC input, or DSP hardware

.

The DSP option can be factory installed in lieu of the HPF hardware, with HPF frequencies set in software to any

value from 20Hz to 20kHz with a slope of 12dB/oct to 48dB/oct and various response options.  In order to have AES/

EBU capability in a constant voltage amplifier, the DSP option must be installed.

Содержание ne 4200.10

Страница 1: ...er NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 www ashly com ne 4250 ne 8250 ne 4250 25 ne 8250 25 ne 4250 70 ne 8250 70 ne 4250 10 ne 8250 10 Network Enabled Multi Channe...

Страница 2: ...6 Front Panel Features 6 Rear Panel Features 7 Installation Requirements 7 Constant Voltage Models 25V 70V and 100V and High Pass Filters 7 4 REMOTE CONTROL 8 On Off Remote Standby 8 Preset Recall 8...

Страница 3: ...OVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPlIANCE TO RAIN OR MOISTURE TO REDUCE THE...

Страница 4: ...ustomer FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accep...

Страница 5: ...to 35 presets subpresets can be stored within the amplifier and can be recalled in real time from a computer WR 5 remote control or contact closure switches up to four 2 AES EBU Input Using an option...

Страница 6: ...tput voltage is 1 2 volt below the output power supply voltage 7 Bridge This LED indicates that the channel pair is selected to BRIDGE mode from the back panel switch and that only the odd input chann...

Страница 7: ...UTION When mounting or connecting the amplifier always disconnect it from the mains Use four screws and washers when mounting the amplifier to the front rack rails Rear support is also recommended esp...

Страница 8: ...isabled from software the front panel DISABLE LED will light The power switch will remain inactive until enabled again from software even if the amp is removed from power Preset Recall The four contac...

Страница 9: ...or visit the Ashly web site at www ashly com for more WR 5 details RD 8C or RW 8C Remote Control A second microprocessor based controller the Ashly RD 8C is an eight channel wall mount level controll...

Страница 10: ...vices are networked Linking of multiple devices is managed through LINK GROUPS Each Proteane device will support up to eight Link Groups DSP function blocks may be assigned to these groups though Prot...

Страница 11: ...ials indicate the physical position of hardware controls on either the amp front panel or the remote level control if present Note that these will display the position of attenuators even when DISABLE...

Страница 12: ...elp Menu Contents and Index Contents Protea NE Products PE Multichannel Amplifiers DSP Control for details of all DSP func tions The key features include 1 Input Channel Number Right click on this to...

Страница 13: ...Hz 20kHz 1 THD 150W 4 ohms 20Hz 20kHz 1 THD 250W Bridge Mode 8 ohms 20Hz 20kHz 1 THD 500W 25 70 100 Volt models 20Hz 20kHz 1 THD per channel 250W Signal to Noise 20Hz 20KHz unweighted 98dB Power Requi...

Страница 14: ...ain Gain off 50dB to 12dB Gain w VCA off 50dB to 12dB WR 5 Remote Gain off 50dB to 12dB Equalization 31 Band Graphic Filter Type constant Q or proportional Bandwidth 0 499oct to 0 25oct 2 4 6 or 10 Ba...

Страница 15: ...l Audio Input Type 110 ohm transformer balanced XLR Sample Rates 48kHz 96kHz Max Cable Length 100 meters 7 WARRANTY INFORMATION The unit you have just purchased is protected by a limited five year war...

Страница 16: ...annel Power Amplifiers ASHLY AUDIO INC 847 Holt Road Webster NY 14580 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly com 2008 by Ashly Audio Corporation All rights reserved world...