Installation instructions are supplied with the air
intake kit. Outside combustion air may be required
if:
1.
Your stove does not draw steadily, smoke roll-out
occurs, wood burns poorly, or back-drafts occur
whether or not there is combustion present.
2.
Existing fuel-fired equipment in the house, such
as fireplaces or other heating appliances, smell,
do not operate properly, suffer smoke roll-out
when opened, or back-drafts occur whether or
not there is combustion present.
3.
Opening a window slightly on a calm (windless)
day alleviates any of the above symptoms.
4.
The house is equipped with a well-sealed vapor
barrier and tight fitting windows and/or has any
powered devices that exhaust house air.
5. There is excessive condensation on windows in
the winter.
6. A ventilation system is installed in the house.
Slide the hose clamp over the aluminium flex pipe.
Then slide the flex pipe over the air intake tube of
the stove. Next tighten the hose clamp over the end
of the aluminium flex hose.
FOR USE IN MOBILE HOMES (U.S. ONLY)
• WARNING! DO NOT INSTALL IN SLEEPING
ROOM.
• CAUTION! THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
• INSTALL IN ACCORDANCE WITH 24 CFR,
PART 3280 (HUD).
• USE A FACTORY BUILT CHIMNEY THAT
COMPLIES WITH UL 103 STANDARDS;
THEREFORE IT MUST BE A TYPE HT (2100°F).
• USE A SPARK ARRESTER.
• THE STOVE MUST BE ATTACHED TO THE
STRUCTURE OF THE MOBILE HOME.
SECURING APPLIANCE’S ON A
PEDESTAL TO THE FLOOR
Use the designated holes to secure the unit to the
floor.
SECURING APPLIANCE’S WITH LEGS TO
THE FLOOR
1.
The bracket engages around the square
extrusion of the leveling bolt inserted into the
leg.
2.
Once appliance is leveled, position the bracket
and attach to the floor using the appropriate
hardware needed for your specific flooring.
3. Install one bracket per leg or consult your local
authority having jurisdiction to determine how
many points of attachment are required.
In addition to the previously detailed installation
requirements, the heater must be electrically
grounded to the steel chassis of the mobile home
with 8 GA copper wire using a serrated or star
washer to penetrate paint or protective coating to
ensure grounding.
CHIMNEY CONNECTOR (STOVE PIPE)
The chimney connector and chimney must have
the same diameter as the stove outlet (6”). If this
is not the case, we recommend you contact your
dealer to ensure there will be no problem with the
INSTALLATION