FLOOR PROTECTOR
This heater must have a non-combustible floor
protector with an R-Value of at least 1.4 installed
beneath it if the floor is constructed of combustible
material. If a floor pad is used, it should be UL listed
or equal. The floor protector should be large enough
to extend under the stove and beyond each side as
indicated. If there is a horizontal run of flue pipe,
there needs to be floor protection under it that
extends two inches beyond either side of the pipe.
REAR
FRONT
SIDE
SIDE
Front
22” (559 mm)
Sides
8” (204 mm)
Rear
*2” (51 mm)
*Canadian Installations require
8” (204 mm) to the rear.
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to
combustible materials be strictly adhered to during
installation of the stove.
•
If there is a horizontal run of flue pipe there must
be at lease 18” of clearance between the pipe and
the ceiling. There also has to be floor protection
under the horizontal run that extends 2” beyond
each side of the flue pipe.
•
Floor to ceiling height must be at least 7’ (2.13m)
in all cases.
•
Do not place any combustible material within 4’
(1.2m) of the front of the unit.
•
The clearance between the flue pipe and a wall
are valid only for vertical walls and for vertical flue
pipe.
• The chimney connector must not pass through
an attic or roof space, closet or similar concealed
space, a floor, or a ceiling.
• For Canadian installations, where passage through
a wall, or partition of combustible construction is
desired, the installation must conform to CAN/
CSA-B365.
•
A flue pipe crossing a combustible wall must have
a minimum clearance of 18” (458 mm).
•
To reduce flue clearances from combustible
materials, contact your local safety department.
D
B
A
C
E
F
E
Single Wall Pipe (Double Wall Pipe)
Key
in
mm
A
15 (12)
381 (305)
B
18 (18)
458 (458)
C
19 (16)
483 (407)
D
29 (29)
737 (737)
E
12 (12)
305 (305)
F
22 (22)
559 (559)
OUTSIDE COMBUSTION AIR
Your wood stove is approved to be installed with
an outside air intake (4FAK) which is necessary
for a mobile home. This type of installation is
also required in air tight houses and houses with
negative pressure problems. You can purchase this
option through your heater dealer. Make sure to
specify the part number mentioned in this booklet.