© 2022 United States Stove Company
9
A. Minimum 4-foot (1.22m) clearance below or
beside any door or window that opens.
B.
Minimum 1-foot (0.3m) clearance above any
door or window that opens.
C.
Minimum 3-foot (0.91m) clearance from any
adjacent building.
D.
Minimum 7-foot (2.13m) clearance from any
grade when adjacent to public walkways.
E. Minimum 2-foot (0.61m) clearance above any
grass, plants, or other combustible materials.
F.
Minimum 3-foot (0.91m) clearance from an
forced air intake of any appliance.
G.
Minimum 2-foot (0.61m) clearance below eves
or overhang.
H.
Minimum 1-foot (0.3m) clearance horizontally
from combustible wall.
I. Must be a minimum of 3 foot (0.91m) above the
roof and 2 foot (0.61m) above the highest point
or the roof within 10 feet (3.05m).
Determining where to install your new pellet stove
heater. To get the most efficient use of re-circulated
heat, you should consider a room that is centrally
located within your home. Choose a room that
is large and open. It is Extremely Important to
maintain proper clearances from any combustible
surfaces or materials in the room where your heater
will be located. You can find proper clearance
measurements in this manual and on the rating
label of your pellet stove. The pellet stove can be
vented through an exterior wall or into an existing
masonry or metal chimney if “PL” vent pipe is used
throughout existing chimney. Venting can pass
through the ceiling and roof if approved pipe is
used. Where passage through a wall, or partition of
combustible construction is desired, the installation
must conform to CAN/CSA-B365.
WARNING:
• DO NOT OBTAIN COMBUSTION AIR FROM
THE ATTIC, GARAGE OR ANY OTHER
UNVENTILATED AREA. YOU MAY OBTAIN
COMBUSTION AIR FROM A VENTILATED
CRAWL SPACE.
• DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER HEATER, FURNACE
OR APPLIANCE.
• INSTALL VENT AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
• ONLY USE APPROVED MATERIAL FOR
INSTALLATION, FAILURE TO DO SO MAY
RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
This appliance is certified for use with listed 3 inch
or 4 inch “PL” pellet venting products. The use of
other components other than stated herein could
cause bodily harm, heater damage, and void your
warranty.
HORIZONTAL EXHAUST VENT
INSTALLATION
1.
Locate your pellet stove in a location which
meets the requirements of this manual, but
in an area where it does not interfere with the
house framing, wiring, etc.
2.
Install a non-combustible hearth pad
underneath the pellet stove. This pad should
extend at least 6” (152 mm) in front of the unit.
3.
Place the pellet stove approximately 15” (381
mm) away from the interior wall.
4. Locate the center of the exhaust pipe of your
unit. This point should then be extended to
the interior wall of your house. Once you have
located the center point, on the interior wall, cut
a 7” (175 mm) diameter hole through the wall.
5.
The next step is to install the wall thimble, refer
to the instructions which come with the wall
thimble for this step.
6. Install the appropriate length of exhaust vent
pipe into the wall thimble. See steps 11 and 12
when determining the correct length of exhaust
vent to use.
7.
Outside Fresh Air is Mandatory when
installing this pellet stove room heater in
INSTALLATION