2.

SAFETY PRECAUTIONS:

Aseptico accepts no liability for direct or consequential injury or damage resulting from improper

use, arising in particular through the non-observance of the operating instructions, or improper

preparation and maintenance.

WARNING:

Clean, disinfect, and sterilize new or repaired handpieces and instruments before

first use and between each patient use. Only use sterilized handpieces and

instruments during treatment. Non-sterilized handpieces and instruments may cause

bacterial or viral infections. Always sterilize handpieces and instruments after

operation.

CAUTION:

Always examine unit components for damage before commencing treatment.

Damaged components must not be used and must be replaced.

WARNING:

Use for intended purposes only. Failure to observe the operating instructions may

result in the patient or user suffering serious injury or the product being damaged,

possibly beyond repair. Before using this product, make sure that you have studied

and understood the operating instructions.

WARNING:

For use by qualified and trained personnel only.

WARNING:

Do not install where there is a risk of an explosion. The Mobile Dental System is not

intended for operation in the presence of flammable anesthetics or gases.

WARNING:

Always operate a high-speed handpiece with water coolant. Operating a high-speed

handpiece without water coolant can cause thermal injury to the patient.

CAUTION:

Observe local regulations concerning disposal of amalgam waste.

WARNING:

Never operate unit or work on patients when the top cover is open.

WARNING:

Do not use this device for dental implant procedures.

CAUTION:

Do not run saline solutions through the water system -- saline will corrode the water

filters.

WARNING:

CONTRAINDICATIONS

Ultrasonic oscillations emitted by the optional Ultrasonic Scaler may prevent the

proper function of cardiac pacemakers. Therefore, Aseptico recommends that

patients with a cardiac pacemaker should not be treated with the Ultrasonic Scaler

component of the AMC-20 Cart.

WARNING:

The optional Ultrasonic Scaler instrument tips oscillate at high frequency and can

fracture during operation. To help prevent the tips from fracturing and possibly

injuring the patient, always follow the scaler manufacturer's operating instructions

and recommended ultrasonic power settings. 

WARNING:

Do not use the optional Ultrasonic Scaler dry. If used dry, the Instrument Tip will heat

immediately. This may cause thermal injury to the tooth. Ensure that adequate liquid

coolant is always available.

WARNING:

Avoid looking directly into the optional Curing Light. Protect patient's eyes with

darkened eyewear when using the Curing Light Probe.

CAUTION:

The lens for the optional electric motor LED is soft and can be damaged. If lens

needs to be cleaned, use a lint-free swab and isopropyl alcohol - do not use other

solvents as they might adversely react with the LED assembly.

CAUTION:

The AEU-5000 Electric Motor is not recommended for use with endodontic files that

have torque limit requirements less than 100 g-cm.

OPTIONAL EQUIPMENT SAFETY PRECAUTIONS:

Содержание AMC-20

Страница 1: ...AMC 20 Mobile Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Страница 2: ...e Note For reliable grounding connect to receptacle marked Hospital Grade To prevent injury to people and damage to property please heed relevant warnings and remarks They are marked as follows WARNIN...

Страница 3: ...n E Type Endodontics Handpiece STANDARD FEATURES Automatic handpiece controls for two pneumatic handpieces Each pneumatic handpiece provides individually controlled water and coolant air 3 way air wat...

Страница 4: ...ons concerning disposal of amalgam waste WARNING Never operate unit or work on patients when the top cover is open WARNING Do not use this device for dental implant procedures CAUTION Do not run salin...

Страница 5: ...color coded to identify different fluids e g sterile water or distilled water 6 Place the foot control on the floor 7 Attach power cord to the back of the unit Fig 5 and plug into a grounded electric...

Страница 6: ...tor into the amalgam manifold Tighten the retaining screw located under the top cover Fig 10 NOTE Before installing the separator into the manifold remove the two caps from the inlet and outlet ports...

Страница 7: ...ESSURE RELEASE TOGGLE BOTTLE SELECTOR TOGGLE AUXILIARY WATER CONNECTION AUXILIARY AIR CONNECTION OPTIONAL SCALER COOLANT VALVE OPTIONAL HANDPIECE SCALER CURING LIGHT HOLDERS ELECTRIC MOTOR CONNECTOR H...

Страница 8: ...10V OUTLET AIR TANK PURGE TOGGLE WASTE COMPARTMENT ACCESS DOOR OPTIONAL 220V OUTLET QUICK DIS CONNECT FOR WASTE HOSE 1 AMP CIRCUIT BREAKERS 2 TANK DRAIN OPTIONAL 10 AMP CIRCUIT BREAKERS 2 FOR 220V 20...

Страница 9: ...PASS FILTER FILTER REGULATOR OPTIONAL FIBER OPTIC CURING LIGHT MODULE SYSTEM PRESSURE GAUGE PRESSURE REGULATOR CENTRAL VACUUM CANNISTER W AMALGAM SOLIDS TRAP INSIDE OPTIONAL OPTIONAL OPTIONAL OPTIONAL...

Страница 10: ...oved from its holder and the foot control is pressed The amount of air pressure supplied to the pneumatic handpieces may be adjusted by turning the flow control screws on the control block OPERATION F...

Страница 11: ...bout 5 seconds after every patient and about 20 seconds at the beginning of each day To flush a handpiece remove it from its holder and point the spray nozzle away from you i e into a basin Flip the f...

Страница 12: ...atio s from the five available options Refer to page 12 for complete instructions on Customizing Ratios 3 Press the SPEED Up Down buttons to select the desired operating speed for the handpiece being...

Страница 13: ...de press the Torque Up Down buttons to select the desired illumination in 10 increments from 10 to 100 The handpiece LED will automatically turn on and change intensity 4 Press the TORQUE Up Down butt...

Страница 14: ...ttings a beep will sound 4 Press the foot pedal to activate the motor and begin operation as the adjustments are made The display icon will blink as the adjustments are made To exit the adjustment mod...

Страница 15: ...100 On FACTORY DEFAULTS The optional Electric Motor Module will retain the factory default settings Fig 25 in memory until changed by the user To recall the original factory defaults press and hold th...

Страница 16: ...ly electric scaler system that provides adjustable ultrasonic levels and a water coolant system The scaler includes 3 instrument tips The 37 instrument is specially developed for subgingival scaling f...

Страница 17: ...alve and control valve are provided to turn coolant to the handpiece and motor On and Off and to control the flow Turn the coolant air control valve clockwise until it seats softly Begin turning count...

Страница 18: ...t the water lines weekly Prepare a 1 10 bleach solution 1 part household bleach to 9 parts water Purge all water lines see page 17 Purging Water From the System Fill water bottles with bleach solution...

Страница 19: ...ll water is purged from the lines with air Finally hold the water syringe over the basin and hold down the water button until all water is purged from the line with air GENERAL CLEANING The external s...

Страница 20: ...e Lazer is a product of Kinetic Instruments Inc The curing probe is fully autoclavable Detach probe by pressing quick disconnect button on side of handle Clean probe with disinfectant then autoclave a...

Страница 21: ...anchor eye bolts on the base as shown in Figure 38 7 Place the foot control pedal under the cart as shown in Figure 39 8 Wrap the cart with palletizer stretch wrap Fig 40 9 Insert the two end panels a...

Страница 22: ...protective foam packing blocks on the front and top of the Cart Ensure the Cart s dental instrument holders are aligned with the cutouts on the top packing block carefully rotate the Cart s pivoting...

Страница 23: ...ressure Insufficient vacuum Insufficient handpiece operation No water to handpiece No coolant air to handpiece Unit is turning On and Off Correction Check system power connection Check voltage selecto...

Страница 24: ...w High Vol open 42 5 liters min 3 8 cm Hg Simultaneous Vacuum High 4 Hg 5 1 SCFM 144 4 liters min 10 2 cm Hg Low 1 5 Hg 1 4 SCFM 39 6 liters min 3 8 cm Hg Vacuum Compressor Pump 115 PSI 7 92 bar 2 HP...

Страница 25: ...e Water Coolant Control Air Coolant ON OFF Toggle OR Flush Toggle Bottle Pressure Release Toggle Bottle Select Toggle Footswitch On Off Switch Mains Temperature Limitation Manufacturer Humidity Limita...

Страница 26: ...LGAM SOLIDS TRAP OPEN TYPE AA 29 1 AMALGAM SOLIDS TRAP OPEN TYPE AA 29 100 100 AMALGAM SOLIDS TRAP CLOSED TYPE AA 290VS 1 AMALGAM SOLIDS TRAP CLOSED TYPE AA 290VS 100 100 VALVE DELUXE UNIVERSL AUTOCLA...

Страница 27: ...of such action In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service will provide instructions usually directing th...

Страница 28: ...P N 420869 Rev M ECO 14212 06 2017 PRINTED IN THE U S A P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com...

Отзывы: