6
3.4. Auto Button
This button is used to turn the
Auto mode
on or off.
3.5. Timer Button
This button is used to set the automatic shut-off timer.
4. LED Display
This unit is equipped with a full function LED display which shows the operating status and condition of the
unit as follows:
4.1. Sensors and Air Quality Indicators
The levels of both Dust particles and the presence of Odors are shown in the LED Display: There are 4
levels for each and as the presence of contaminants increases, the Air Quality Indicators will change to
show less than optimal air quality. As the air quality improves, the indicators will show the air quality as
indicated below:
Contaminant Level
Minimal
Low
Medium High
Air Quality Level
Very Clean Clean Good Average Poor
Fan Speed
Quiet
Low Medium High
Fan Speed Indicator Color*
Green
Blue Orange Red
* When operating in Auto Mode.
4.2. Check Filter Indicator
After a total of 3,000 cumulative hours (125 days) of operation since the last reset, the
Check Filter
indicator on the LED Display will illuminate as a reminder that you should check the filters and clean or
replace as necessary. If the prefilter is dirty hand wash, rinse and hang to dry, DO NOT MACHINE WASH.
Check the HEPA filter against the color shade guide on the filter frame
to see if replacement is necessary.
Filters and ultraviolet germicidal lamps should be replaced at least once every 12 months to provide
optimal efficiency and performance. If your air quality is particularly poor, you may need to replace more
often.