USER’S MANUAL

PP60 pH

EN

PERISTLATIC PUMP FOR pH REGULATION 

www.asekopool.com

Содержание 13260

Страница 1: ...USER S MANUAL PP60 pH EN PERISTLATIC PUMP FOR pH REGULATION www asekopool com...

Страница 2: ...osing of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and o...

Страница 3: ...s wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy materia...

Страница 4: ...pump 12117 Injecrion valve 12005 Suction tube weight 12023 Dowels and screws PE Tube 1 4 6 35 mm transparent 12008 PP60 pH 13260 pH probe Long Life 12012 Probe wrench 13046 Measuring Water Valve 2 pc...

Страница 5: ...CZ 5 Accessories Original aseko chemicals Vlepovac z tka se z vitem 1 4 12134 pH Buffer 7 00 12065 pH MINUS 20l 12130 pH MINUS 5l 12131 pH PLUS 20l 12120 pH PLUS 5l 12136 Fotometr 13076...

Страница 6: ...dry and dust free environment with temperature ranging from 5 C to 40 C To mount the device use the mounting holes that are accessible after opening the front cover of the device To mount the device u...

Страница 7: ...connector ring After probes have been inserted slightly tightened and connectors have been connected PP60 pH is ready for connection to the water system of your pool WARNING Only hand tighten the pro...

Страница 8: ...f delivery The use of scissors or tongs deforms the tube end and leads to leaks WARNING Only hand tighten Do not use tongs or any other tools 1 To ensure tightness of joints cut the tube at 90 angle U...

Страница 9: ...OUTLET CAN BE REALISED 1 downstream of filtration 2 to non pressure overflow tank TO POOL Heating FROM POOL Sampling point for callibration POOL WATER INLET IN IN OUT OUT Besgo Coagulation mixer Max...

Страница 10: ...ush the PE tube through the cap Select the tube distance so that the tube reaches the canister bottom and can be connected to the pump as straight as possible A long tube in the canister would bend an...

Страница 11: ...CZ 11 Max 8 m Max 8 m Max 2 m TO POOL Heating FROM POOL Besgo Coagulation mixer Sampling point for callibration...

Страница 12: ...shows the dose in ml Press the OK button to start manual dosing and monitor the process of the OK button to start manual dosing and monitor the process of the OK dosing liquid in the transparent tubes...

Страница 13: ...inlet to probes and furthermore from the water outlet from probes to the closing valve Check condition of the extraction valve and the closing valve and their seals for being clogged and their closed...

Страница 14: ...Lubricate the new hose with the supplied special grease Insert the lubricated hose into the cassette Place the cover cassette back on PP60 pH and turn it clockwise to lock it Use new nuts which are pa...

Страница 15: ...CZ 15...