EN
31
ASIN Aqua NET
ASIN Aqua error messaging
The agent has run out.
Check the chlorine and pH agents regularly so that they
do not run out. Chlorine agent concentration is 15-20%.
This degrades over time and if exposed to direct sunlight.
The dosing pump does not work.
Check that your dosing pumps are securely fi tted and not loose.
Check the connections to your dosing pumps are secure and not leaking.
Check the clear plastic tubes inside the dosing
pumps are not damaged or broken.
To remove your dosing pumps from your ASIN Aqua, disconnect the clear plastic
tubes, turn your dosing pump anti clockwise and pull away from your ASIN Aqua.
The dosing valve is not working.
Check your dosing valves regularly for the build up of limescale.
Make sure dust and dirt does not get into the containers of the chlorine
and pH agent to avoid blockages and damage to the valves.
Check the rubber seals of your valves regularly to prevent leaking.
Water does not flow to the probes.
Check the clear plastic tubes connection to your
ASIN Aqua Redox for damage and leaks.
Check the connection of the clear plastic tubes
to the valves for damage and leaks.
Check the valves are properly connected to the water supply and
that they are not damaged, blocked or in the closed position.
The probe does not work.
Replace the pH probe each year.
Ensure your probes are clean and free from dirt.
Exposure to below 0° C conditions damages the probes.
Regular cleaning of the probes maintains system accuracy.
pH and Chlorine display ERROR messages
Press the red ERROR box to see the faults.
Ensure the chlorine pump is connected to the
chlorine agent and pH pump to pH agent.
After 30/60
doses of chlorine
agent without
probe response
displays this
error message.
After 15/30
doses of pH
agent without
probe response
displays this
error message.