EN
11
ASIN Aqua NET
WASTE
WASTE
31,5
14
31,5
AIR °C
RH %
SETTINGS
750
REDOX
7,0
pH
ASIN Aqua
POOL WATER °C
OK
EXTERNAL TOUCH
DISPLAY
Water-filling
Heating
Thermo-
meter
If you use automatic water-filling we
recommend you to install it AFTER the
measuring-water connection. If you connect
auto water-filling BEFORE measuring-water
connection you must TURN OFF
the ASIN Aqua.
Water supply
for the probes (IN)
Water
supply
Only hand tighten
the connections.
Do not use pliers
or wrench.
Water outlet from probes (OUT)
Water from the
CLF probe
must led to no pressure.
For example to Buffer
tank, skimmer or waste.
Water from the
REDOX probe
can be
connected before
filtration pump.
*)
CHLOR
pH-
For best results, we recommend
use of original ASEKO or similarly
based water treatment agents.
WARNING:
Use of hydrochloric acid based
agents is strictly prohibited!
pH 20%
Chlor 13 – 17%
Drill a hole
in the lid
for the tube
Ø 1 mm
Ø 6,2 mm
RCD
Current
protector
30 mA
230 V / 50 Hz
Internet LAN
*)