background image

Aseko Pool Technology

EN

asekopool.com

ASIN Aqua

®

NET

Содержание 12034

Страница 1: ...Aseko Pool Technology EN asekopool com ASIN Aqua NET...

Страница 2: ...2 ASIN Aqua NET ASIN Aqua...

Страница 3: ...3 ASIN Aqua NET ENG USER S MANUAL ASIN Aqua NET REDOX 12035 ASIN Aqua NET CLF 12036 ASIN Aqua NET DOSE 12034...

Страница 4: ...be 1 4 Water Valve 2 pc ASIN Aqua What you receive in your box Sharp knife Screws and dowels pH probe pH probe Flowmeter Filter CLF chlorine free probe CLF chlorine free probe CLF chlorine free probe...

Страница 5: ...6 Manual Dosing 17 Set the parameters of your swimming pool 17 pH Settings 18 pH Calibrating 18 Choose the function of Your ASIN Aqua 20 1 Free chlorine probe CLF 20 2 Redox probe RX 22 3 Time dosing...

Страница 6: ...ng of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and or s...

Страница 7: ...is wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy mater...

Страница 8: ...ols With a touch screen interface you have complete control over measurement and regulation of your pool ASIN Aqua operates with your existing pool filtering equipment ASIN Aqua works also on time dos...

Страница 9: ...tic pump Peristaltic pump for pH agent for pH agent Cable for Redox or CLF probe Peristaltic pump Peristaltic pump for desinfection agent for desinfection agent Tube fitting Tube fitting Water INLET f...

Страница 10: ...e weather conditions cause damage ASIN Aqua functional temperature range is 5 40 C WARNING Ensure pool water is chemically clean and free from dirt before installing your ASIN Aqua Do not install your...

Страница 11: ...ust TURN OFF the ASIN Aqua Water supply for the probes IN Water supply Only hand tighten the connections Do not use pliers or wrench Water outlet from probes OUT Water from the CLF probe must led to n...

Страница 12: ...ter 1 Insert your CLF or Redox probe in the left side of your ASIN Aqua and attach the cable using the screw fit connector 2 Insert your pH probe in the right side of your ASIN Aqua and attach the cab...

Страница 13: ...the left and the water output on the right Make sure the water pressure is not more than 1 5 bar 3 The water output from your ASIN Aqua can be connected on the tubing before the pump or to the skimme...

Страница 14: ...the chlorine pump of your ASIN Aqua 5 Connect your clear plastic tube from the right side of your chlorine pump to your chlorine injection valve Thread G 1 4 6 Ensure your valves are not blocked or da...

Страница 15: ...ASIN Aqua is used in a different manner not specified by the manufacturer the apparatus may not provide the full protection it is designed for RECOMMENDED To frequent switching ON OFF more the 4x a d...

Страница 16: ...ction allows you to test both pumps 1 From the start screen select SETTINGS 2 Select DOSING TEST 3 Select START in the yellow box on the left of the screen This starts the chlorine pump on the left of...

Страница 17: ...nt within your pool This is required if the concentration is significantly below recommended levels You can also use Manual dosing to test the connections of the clear plastic tubes to the pH and chlo...

Страница 18: ...r chlorine sanitized pools You can use pH 7 0 pH Calibrating WARNING The probes do NOT require calibration under most circumstances ASEKO calibrates the ASIN Aqua pH probes at the factory If you do no...

Страница 19: ...lly If different adjust the reading on the ASIN Aqua by pressing the and buttons so that they match and press OK to save RECOMMENDATION for precision calibrating use the test buffer pH 7 00 If the man...

Страница 20: ...h the following screen 1 If You have free chlorine probe Your Asin Aqua is already installed connected to pool water and to chemical agents Set up the chlorine level to 0 0 mg l Set up the pH value to...

Страница 21: ...IN Aqua with the reading taken manually If different adjust the reading on the ASIN Aqua by pressing the and buttons so that they match and press OK to save When your manual chlorine readings match th...

Страница 22: ...on agent directly to pool Fine tune Manuallly check the chlorine level in the pool water If the pool s chlorine level is to low or high adjust the mV redox settings to fine tune your system Each 0 1 m...

Страница 23: ...m3 per hour if you use the chlorine sanitation agent Set up the sanitation dosing volume on 10 ml m3 per day if you use the active oxygen sanitation agent Set up the pH value to 6 8 Fine tune Manuall...

Страница 24: ...after 60 doses ASIN Aqua stops dosing For swimming pools If the probe output signal does not change after 30 doses ASIN Aqua stops dosing pH value change too fast This can be done by water filling di...

Страница 25: ...PORT 47524 the route must not be blocked by the firewall Connection of ASIN AQUA Net to your LAN is not complicated You just need some basic IT skills If you are not enough skilled to setup the conne...

Страница 26: ...set parameters are exceeded Shows actual parameters and also history App is available for iOS and Android Pool LIVE Enter serial number of the device you want to monitor You can set the notification...

Страница 27: ...ter quality by using well arranged graphs Shows all measured data and actions up to 30 days back All operations are monitored in real time Login registration screen Overview of all devices Overview of...

Страница 28: ...ose which parameters you want to see on the display Thermometer connection Install temp holder to the pipe system then insert the thermometer Connect the cable 2m as standard other lengths on request...

Страница 29: ...tube change is made in the following way Turn the pump counterclockwise and remove it Loosen both ends of the tube and remove the tube Cut the tie strips and release the tube Use a new tube and secur...

Страница 30: ...ce every 6 months PH and Chlorine Pumps Check inside the pumps for damage The clear plastic tubes wear out during operation Replace tubes every 12 months 12073 Item Maintenance Procedure Recommendatio...

Страница 31: ...ne and pH agent to avoid blockages and damage to the valves Check the rubber seals of your valves regularly to prevent leaking Water does not flow to the probes Check the clear plastic tubes connectio...