AC90LC-3, AC100LC-3, and AC125LC-3 Operations Manual....
19
5.2
WATER LINE PLUMBING
All water line connections are to be made using 1/2" NPT fittings. Use Teflon sealant to
ensure that no leakage will occur.
Isolation valves must be installed locally for maintenance purposes, and so that shutoff can
occur in the event of a water leak.
The ASEA-supplied Flow Control Solenoid must be installed and located within 24" of the
bottom right front corner of the converter as dictated by the supplied control cable length.
The ASEA-supplied Flow Control Solenoid is directional and must be installed in
accordance with the marking in the brass body at the inlet side.
Condensation may occur on the heat exchanger body based on humidity levels in the
environment. The installer should design the area around the converter accordingly. If
insolation is added to the exchanger, DO NOT insulate the body of the Flow Control
Solenoid.
To ensure that no air becomes trapped in the heat exchanger unit, route the water return line
above the level of the heat exchange unit before connection to the return main.
The heat exchanger unit is constructed of 90/10 cuprous nickel. There is a zinc pencil anode
located on the heat exchanger unit end bell.
No maintenance need be performed on the heat exchanger unit other than periodic checking
of the zinc pencil anode when used in a chilled, fresh water system.
A water flow rate greater than 16 GPM (Gallons Per Minute) is wasteful and can accelerate
water erosion of the heat exchange unit’s cuprous nickel piping.
Содержание AC100LC-3
Страница 42: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 42 This page intentionally left blank ...
Страница 58: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 58 8 DIAGNOSTICS cont FIGURE 12 STATUS BIT DEFINITIONS ...
Страница 62: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 62 11 MSDS SHEET COOLANT OIL ...
Страница 63: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 63 11 MSDS SHEET COOLANT OIL cont ...
Страница 64: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 64 11 MSDS SHEET COOLANT OIL cont ...
Страница 65: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 65 11 MSDS SHEET COOLANT OIL cont ...
Страница 66: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 66 11 MSDS SHEET COOLANT OIL cont ...
Страница 67: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 67 11 MSDS SHEET COOLANT OIL cont ...
Страница 68: ...AC90LC 3 AC100LC 3 and AC125LC 3 Operations Manual 68 11 MSDS SHEET COOLANT OIL cont ...