Ascon tecnologic KX6 Series Скачать руководство пользователя страница 2

Ascon Tecnologic - KX6 Series - ENGINEERING MANUAL - Vr. 0.0

 PAG. 2

2.  ConneCtion diAgrAm

Thermocouple

DI1

Out1 (2A)

Out2 (2A)

Out3 (2A)

Out4 (2A)

Analogue Input

RS485

mA

Neutral

100... 240 VAC

100... 240 VAC

24 VAC/VDC

C

NO

NO

C

Phase

1

2

2

1

4

3

6

5

8

7

10

9

12

11

NO

14

13

16

15

18

17

20

19

22

21

24

23

NO

C

IN1

IN2

GND

D-

D+

DI2

Potentiometer

100

... 10 k

2.1  generAl notes About wiring

1. 

Do not run input wires together with power cables.

2. 

External components (like zener barriers, etc.) connected 
between sensor and input terminals may cause errors in 
measurement due to excessive and/or not balanced line 
resistance or possible leakage currents.

3. 

When a shielded cable is used, it should be connected at 
one point only.

4. 

Pay attention to the line resistance; a high line resistance 
may cause measurement errors.

2.2  inputs

2.2.1  thermocouple input

1

2

+

_

external resistance:

 100

 max., maximum error 25 

m

V.

Cold junction:

 automatic compensation between 0... 50°C.

Cold junction accuracy:

 0.05°C/°C after a warm-up of 

20 minutes.

input impedance:

 > 1 M

.

Calibration:

 According to EN 60584-1.

note: 

For TC wiring use proper compensating cable 
preferable shielded.

2.2.2  mA input

0/4... 20 mA input wiring for passive transmitter 
using an external power supply

+

_

+

_

1

2

0/4...20 mA

Passive

transmitter

_

External

PWS

+

input impedance:

 < 50

W

.

0/4... 20 mA input wiring for active transmitter

0/4...20 mA

Active

transmitter

+

_

+

_

1

2

input impedance:

 < 50

W

.

2.2.3  digital inputs

note: 

The instrument needs 150 ms to recognize a contact 
status variation;

Digital input 1 driven by dry contact

3

4

Digital 
input 1

maximum contact resistance:

 100

.

Contact rating:

  10 V, 6 mA.

notes: 1. 

Logic input 1 is 

not

 isolated from the measuring 

input.  A double or reinforced isolation between 
logic input 1 and power line must be ensured by 
external elements.

2. 

Do not run logic input wiring together with power 
cables.

Digital input 2 driven by 24 VAC/DC or 100... 240 VAC

22

23

24

Digital
input 2

100... 240 VAC

Common

24 VAC/DC

notes: 1. 

The isolated DI2 Digital Input must be used  

in only one

 of the two available connections: 

• High level input (100... 240 VAC);

 

• Low level input (24 VDC/AC).

2. 

The terminals of logic input 2 (high/low level) are 
isolated from the measuring input.  In this way, the 
instrument itself ensures a double or reinforced isola-
tion between logic input 2 terminals and power line.

2.2.4  potentiometer input

Safety notes:

Do not run potentiometer input wiring together with power 
cables.

13

14

15

Potentiometer
100

... 10 k

Input 2

potentiometer value:

 From 100

 to 10 k

.

Содержание KX6 Series

Страница 1: ...r permanent installation for indoor use only in an electrical panel which encloses the rear housing exposed terminals and wiring on the back Select a mounting location having the following characteris...

Страница 2: ...0 mA input wiring for passive transmitter using an external power supply _ _ 1 2 0 4 20 mA Passive transmitter _ External PWS Input impedance 50W 0 4 20 mA input wiring for active transmitter 0 4 20 m...

Страница 3: ...4 NO 9 C NO Alarm 1 OP3 Alarm 2 OP4 Load AC 8 10 Load Contact rating 2 A 250 V cosj 1 1 A 250 V cosj 0 4 Operation 1 x 105 2 4 Serial Interface RS 485 D D GND 17 18 16 D D GND D D GND D D GND Interfac...

Страница 4: ...0 023 in Weight 160 g max Power supply 100 240 VAC 15 10 of the nominal value Power consumption 5 VA max Insulation voltage 2300 V rms according to EN 61010 1 Display updating time 500 ms Sampling tim...

Страница 5: ...s to take advantage of all instrument features The instrument have one complete parameter set indicated as Configuration parameter set or Configuration parameters The access to the configuration param...

Страница 6: ...buttons set the value 581 3 Push button 4 The instrument turns ON all the LEDs for a few seconds then returns to the Standard display mode Notes 1 If the instrument does NOT TURN ON ALL the LEDs for...

Страница 7: ...out 2 output while the values greater than zero activate the Open valve out 1 output 4 When ON OFF control is programmed and an out of range is detected the instrument performs the safety output valu...

Страница 8: ...tion low alarm relative HidE Deviation high alarm relative LHdo Relative band alarm with alarm indication out of the band LHdi Relative band alarm with alarm indication inside the band Notes 1 The rel...

Страница 9: ...1010 mBar but this value is out of range The reset can be made only by turning the instrument OFF removing the condition that generate the alarm and then turn the instrument ON again All band alarms u...

Страница 10: ...to 0 the tempera ture must go down if not the SSR is in short circuit the valve is jammed and so on So the LBA should be generated LBA function is automatically enabled when the PID requires the maxi...

Страница 11: ...7 EvoTune with manual start 8 EvoTune with automatic restart at all set point change 41 tunE Manual start of the auto tune Available Always Range oFF The instrument is not performing the auto tune on...

Страница 12: ...start time Available When 39 cont PID or 39 cont 3Pt and 58 Pot Pot c Range oFF Function not used 0 01 7 59 hh mm inF Soft start always active Note The time calculation starts at Power ON and is inte...

Страница 13: ...Note For other details see 61 SPLL parameter 63 SP Set Point 1 Available Always Range From 61 SPLL to 62 SPHL engineering units 64 SP 2 Set Point 2 Available When 60 nSP 2 Range From 61 SPLL to 62 SP...

Страница 14: ...The first press puts the in strument in stand by mode while a second one puts the instrument in Auto mode SP1 2 SP SP2 selection Notes 1 When SP1 2 is used every press of the button longer than 1 sec...

Страница 15: ...ence between AL P and AH P is equal to 10 Engineering Units 87 AL o Adjust Low Offset Available Always Range 300 300 engineering units 88 AH P Adjust High Point Available Always Range From AL P 10 to...

Страница 16: ...L2 Pb A 7 Pb ti A 8 ti td A 9 td Aut r A 10 Aut r Now proceed as follows 1 Push the button for more than 3 seconds The upper display will show PASS while the middle display shows 0 2 By and buttons se...

Страница 17: ...assword Notes 1 The factory default password for configuration parameters is 20 2 Operator and assistace level of Parameter modification are protected by a time out If no button is pressed for more th...

Страница 18: ...always on display and no button is pressed for more than the programmed time out the display goes OFF and only 4 segments of the less significant digit are turned ON in sequence in order to show that...

Страница 19: ...lectrical equipment for measurement control and laboratory use for this reason it could not be used as a safety equipment Whenever a failure or a malfunction of the control device may cause dangerous...

Страница 20: ...to use it ti configure other instruments To transfer a complete instrument configuration to a PC or from a PC to an instrument To transfer a complete instrument configuration from a PC to an instrumen...

Страница 21: ...Digital Input 2 function oFF 11 di A Digital Inputs Action DI2 only if configured 0 DI1 direct action DI2 direct action 1 DI1 reverse action DI2 direct action 2 DI1 direct action DI2 reverse action 3...

Страница 22: ...n stand by mode 2 Alarm 1 enabled in out of range condition 3 Alarm 1 enabled in stand by mode and in out of range condition 0 AL2 group no Param Description Dec Point Values Default 27 AL2t Alarm 2 t...

Страница 23: ...ower up and after a set point change 5 Evo tune with automatic restart at every power up 6 Evo tune with automatic start the first power up only 7 Evo tune with manual start 8 Evo tune with automatic...

Страница 24: ...nction tunE Auto tune self tune enabling A single press longer than 1 se cond starts the auto tune oPLo Manual mode The first pressure puts the instrument in manual mode oPLo while a second one puts t...

Страница 25: ...ted Master nonE Retransmission not used the instrument is a slave rSP The instrument becomes a Master and retransmits the operative set point PErc The instrument become a Master and it retransmits the...

Страница 26: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 26...

Страница 27: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 27...

Страница 28: ...Ascon Tecnologic KX6 Line ENGINEERING MANUAL Vr 0 0 PAG 28...

Отзывы: